Literature DB >> 17177440

Coupling molecular beacons to barcoded metal nanowires for multiplexed, sealed chamber DNA bioassays.

Rebecca L Stoermer1, Kristin B Cederquist, Sean K McFarland, Michael Y Sha, Sharron G Penn, Christine D Keating.   

Abstract

We have combined molecular beacon (MB) probes with barcoded metal nanowires to enable no-wash, sealed chamber, multiplexed detection of nucleic acids. Probe design and experimental parameters important in nanowire-based MB assays are discussed. Loop regions of 24 bases and 5 base pair stem regions in the beacon probes gave optimal performance. Our results suggest that thermodynamic predictions for secondary structure stability of solution-phase MB can guide probe design for nanowire-based assays. Dengue virus-specific probes with predicted solution-phase DeltaG of folding in 500 mM buffered NaCl of approximately -4 kcal/mol performed better than those with DeltaG > -2 or < -6 kcal/mol. Buffered 300-500 mM NaCl was selected after comparison of several buffers previously reported for similar types of assays, and 200-500 mM NaCl was found to be the optimal ionic strength for the hybridization temperatures (25 and 50 degrees C) and probe designs used here. Target binding to the surface as a function of solution concentration fit a Sips isotherm with Kd = 1.7 +/- 0.3 nM. The detection limit was approximately 100 pM, limited by incomplete quenching. Single base mismatches could be discriminated from fully complementary targets. Oligonucleotide target sequences specific for human immunodeficiency, hepatitis C, and severe acute respiratory viruses were assayed simultaneously in a no-wash, sealed chamber, multiplexed experiment in which each of three probe sequences was attached to a different pattern of encoded nanowires. Finally, we demonstrated that probe-coated nanowires retain their selectivity and sensitivity in a triplexed assay after storage for over 3 months.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17177440      PMCID: PMC2849162          DOI: 10.1021/ja0658261

Source DB:  PubMed          Journal:  J Am Chem Soc        ISSN: 0002-7863            Impact factor:   15.419


  55 in total

1.  A fiber-optic evanescent wave DNA biosensor based on novel molecular beacons.

Authors:  X Liu; W Tan
Journal:  Anal Chem       Date:  1999-11-15       Impact factor: 6.986

2.  Screening unlabeled DNA targets with randomly ordered fiber-optic gene arrays.

Authors:  F J Steemers; J A Ferguson; D R Walt
Journal:  Nat Biotechnol       Date:  2000-01       Impact factor: 54.908

3.  Molecular beacons for DNA biosensors with micrometer to submicrometer dimensions.

Authors:  X Liu; W Farmerie; S Schuster; W Tan
Journal:  Anal Biochem       Date:  2000-07-15       Impact factor: 3.365

4.  Using molecular beacons to detect single-nucleotide polymorphisms with real-time PCR.

Authors:  M M Mhlanga; L Malmberg
Journal:  Methods       Date:  2001-12       Impact factor: 3.608

5.  Submicrometer metallic barcodes.

Authors:  S R Nicewarner-Pena; R G Freeman; B D Reiss; L He; D J Pena; I D Walton; R Cromer; C D Keating; M J Natan
Journal:  Science       Date:  2001-10-05       Impact factor: 47.728

6.  Multiplex detection of four pathogenic retroviruses using molecular beacons.

Authors:  J A Vet; A R Majithia; S A Marras; S Tyagi; S Dube; B J Poiesz; F R Kramer
Journal:  Proc Natl Acad Sci U S A       Date:  1999-05-25       Impact factor: 11.205

7.  Efficiencies of fluorescence resonance energy transfer and contact-mediated quenching in oligonucleotide probes.

Authors:  Salvatore A E Marras; Fred Russell Kramer; Sanjay Tyagi
Journal:  Nucleic Acids Res       Date:  2002-11-01       Impact factor: 16.971

Review 8.  Molecular beacon DNA probes and their bioanalytical applications.

Authors:  Timothy J Drake; Weihong Tan
Journal:  Appl Spectrosc       Date:  2004-09       Impact factor: 2.388

Review 9.  Molecular interactions on microarrays.

Authors:  E Southern; K Mir; M Shchepinov
Journal:  Nat Genet       Date:  1999-01       Impact factor: 38.330

10.  Use of a multiplex molecular beacon platform for rapid detection of methicillin and vancomycin resistance in Staphylococcus aureus.

Authors:  Daniel Sinsimer; Surbhi Leekha; Steven Park; Salvatore A E Marras; Larry Koreen; Barbara Willey; Steve Naidich; Kimberlee A Musser; Barry N Kreiswirth
Journal:  J Clin Microbiol       Date:  2005-09       Impact factor: 5.948

View more
  13 in total

Review 1.  Surface-enhanced Raman scattering biomedical applications of plasmonic colloidal particles.

Authors:  Sara Abalde-Cela; Paula Aldeanueva-Potel; Cintia Mateo-Mateo; Laura Rodríguez-Lorenzo; Ramón A Alvarez-Puebla; Luis M Liz-Marzán
Journal:  J R Soc Interface       Date:  2010-05-12       Impact factor: 4.118

2.  Nanodisk codes.

Authors:  Lidong Qin; Matthew J Banholzer; Jill E Millstone; Chad A Mirkin
Journal:  Nano Lett       Date:  2007-11-28       Impact factor: 11.189

Review 3.  Nanowire sensors for multiplexed detection of biomolecules.

Authors:  Bo He; Thomas J Morrow; Christine D Keating
Journal:  Curr Opin Chem Biol       Date:  2008-10       Impact factor: 8.822

4.  Nanostructures Enabled by On-Wire Lithography (OWL).

Authors:  Adam B Braunschweig; Abrin L Schmucker; Wei David Wei; Chad A Mirkin
Journal:  Chem Phys Lett       Date:  2010-02-12       Impact factor: 2.328

5.  Shape-coded silica nanotubes for multiplexed bioassay: rapid and reliable magnetic decoding protocols.

Authors:  Bo He; Sung Kyoung Kim; Sang Jun Son; Sang Bok Lee
Journal:  Nanomedicine (Lond)       Date:  2010-01       Impact factor: 5.307

6.  Hybridization efficiency of molecular beacons bound to gold nanowires: effect of surface coverage and target length.

Authors:  Kristin B Cederquist; Christine D Keating
Journal:  Langmuir       Date:  2010-11-01       Impact factor: 3.882

7.  Organically modified silicas on metal nanowires.

Authors:  Stacey L Dean; Joshua J Stapleton; Christine D Keating
Journal:  Langmuir       Date:  2010-09-21       Impact factor: 3.882

8.  Complementary electrical and spectroscopic detection assays with on-wire-lithography-based nanostructures.

Authors:  Gengfeng Zheng; Xiaodong Chen; Chad A Mirkin
Journal:  Small       Date:  2009-11       Impact factor: 13.281

9.  Molecular beacon-metal nanowire interface: effect of probe sequence and surface coverage on sensor performance.

Authors:  Kristin B Cederquist; Rebecca Stoermer Golightly; Christine D Keating
Journal:  Langmuir       Date:  2008-07-15       Impact factor: 3.882

10.  Asymmetric van der Waals forces drive orientation of compositionally anisotropic nanocylinders within smectic arrays: experiment and simulation.

Authors:  Benjamin D Smith; Kristen A Fichthorn; David J Kirby; Lisa M Quimby; Derek A Triplett; Pedro González; Darimar Hernández; Christine D Keating
Journal:  ACS Nano       Date:  2013-12-11       Impact factor: 15.881

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.