Abstract

BACKGROUND: Automated blood culture systems are not FDA-approved for sterility testing of human cells, tissues, or cellular- or tissue-based products. It was previously demonstrated that BacT/ALERT (bioMérieux) and Bactec (Becton Dickinson) were superior to the manual CFR method described in the general biologics regulations, in rates of detection and time to detection of organisms seeded into mock mononuclear cell products with a variety of background media and antibiotics. In this study, the two automated systems were compared to the CFR method for sterility testing of actual cell therapy products manufactured in our facility. STUDY DESIGN AND METHODS: Over a 36-month period, in-process and final product samples from all cell therapy products manufactured in our facility were tested for sterility both by the CFR method and by either BacT/ALERT or Bactec. Products were categorized according to collection and processing variables for analysis of results.
RESULTS: For 1617 samples of a broad range of cell therapy products, rates of true-positive tests were comparable for the automated and CFR methods (2.3% vs. 2.1%), but the CFR method had higher rates of false-positive results (7.3% vs. 0.2%). For automated systems, time to detection of organisms was equivalent to, or faster than, the CFR method.
CONCLUSION: Compared to the CFR method, both BacT/ALERT and Bactec are more sensitive, faster in time to detection, less prone to false-positive results, and less labor-intensive. Both of these automated systems are suitable for sterility testing of cell therapy products after site-specific validation has been performed.

Entities:  

Mesh:

Year:  2006        PMID: 17176318     DOI: 10.1111/j.1537-2995.2006.01041.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  11 in total

Review 1.  Manufacture of tumor- and virus-specific T lymphocytes for adoptive cell therapies.

Authors:  X Wang; I Rivière
Journal:  Cancer Gene Ther       Date:  2015-02-27       Impact factor: 5.987

2.  Comparison of the Bactec 9240 and BacT/Alert blood culture systems for evaluation of placental cord blood for transfusion in neonates.

Authors:  Stefan Riedel; Alan Junkins; Paul D Stamper; Gretchen Cress; John A Widness; Gary V Doern
Journal:  J Clin Microbiol       Date:  2009-04-15       Impact factor: 5.948

3.  Guidelines for preventing infectious complications among hematopoietic cell transplantation recipients: a global perspective.

Authors:  Marcie Tomblyn; Tom Chiller; Hermann Einsele; Ronald Gress; Kent Sepkowitz; Jan Storek; John R Wingard; Jo-Anne H Young; Michael J Boeckh; Michael A Boeckh
Journal:  Biol Blood Marrow Transplant       Date:  2009-10       Impact factor: 5.742

4.  Prospective Evaluation of a Practical Guideline for Managing Positive Sterility Test Results in Cell Therapy Products.

Authors:  Sandhya R Panch; Thejaswi Bikkani; Vanessa Vargas; Jolynn Procter; James W Atkins; Virginia Guptill; Karen M Frank; Anna F Lau; David F Stroncek
Journal:  Biol Blood Marrow Transplant       Date:  2018-08-09       Impact factor: 5.742

5.  Use of the BacT/alert system for rapid detection of microbial contamination in a pilot study using pancreatic islet cell products.

Authors:  Laura Murray; Neil McGowan; John Fleming; Laura Bailey
Journal:  J Clin Microbiol       Date:  2014-07-16       Impact factor: 5.948

6.  Microbial growth in neonatal intravenous fat emulsion administered over 12 versus 24 hours.

Authors:  Bethany M Dedonato; Lisa I Bickford; Ryan J Gates
Journal:  J Pediatr Pharmacol Ther       Date:  2013-10

Review 7.  Sterility Testing for Cellular Therapies: What Is the Role of the Clinical Microbiology Laboratory?

Authors:  James E T Gebo; Anna F Lau
Journal:  J Clin Microbiol       Date:  2020-06-24       Impact factor: 5.948

8.  Comprehensive Evaluation of Compendial USP<71>, BacT/Alert Dual-T, and Bactec FX for Detection of Product Sterility Testing Contaminants.

Authors:  Matthew R England; Frida Stock; James E T Gebo; Karen M Frank; Anna F Lau
Journal:  J Clin Microbiol       Date:  2019-01-30       Impact factor: 5.948

9.  Comprehensive Study Identifies a Sensitive, Low-Risk, Closed-System Model for Detection of Fungal Contaminants in Cell and Gene Therapy Products.

Authors:  Nicole E Putnam; Anna F Lau
Journal:  J Clin Microbiol       Date:  2021-08-18       Impact factor: 5.948

Review 10.  Cell-Based Therapy Manufacturing in Stirred Suspension Bioreactor: Thoughts for cGMP Compliance.

Authors:  Suman C Nath; Lane Harper; Derrick E Rancourt
Journal:  Front Bioeng Biotechnol       Date:  2020-11-26