Literature DB >> 17175100

Preconcentration of Pb(II), Cr(III), Cu(II), Ni(II) and Cd(II) ions in environmental samples by membrane filtration prior to their flame atomic absorption spectrometric determinations.

Umit Divrikli1, Aslihan Arslan Kartal, Mustafa Soylak, Latif Elci.   

Abstract

A method for separation-preconcentration of Pb(II), Cr(III), Cu(II), Ni(II) and Cd(II) ions by membrane filtration has been described. The method based on the collection of analyte metal ions on a cellulose nitrate membrane filter and determination of analytes by flame atomic absorption spectrometry (FAAS). The method was optimized for several parameters including of pH, matrix effects and sample volume. The recoveries of analytes were generally in the range of 93-100%. The detection limits by 3 sigma for analyte ions were 0.02microgL(-1) for Pb(II), 0.3microgL(-1) for Cr(III), 3.1microgL(-1) for Cu(II), 7.8microgL(-1) for Ni(II) and 0.9microgL(-1) for Cd(II). The proposed method was applied to the determination of lead, chromium, copper, nickel and cadmium in tap waters and RM 8704 Buffalo River Sediment standard reference material with satisfactory results. The relative standard deviations of the determinations were below 10%.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17175100     DOI: 10.1016/j.jhazmat.2006.11.040

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  7 in total

1.  Improving photoelectrochemical reduction of Cr(VI) ions by building α-Fe2O3/TiO2 electrode.

Authors:  Pingping Wang; Faqin Dong; Mingxue Liu; Huichao He; Tingting Huo; Lei Zhou; Wei Zhang
Journal:  Environ Sci Pollut Res Int       Date:  2018-02-19       Impact factor: 4.223

2.  Preconcentration of trace elements from water samples on a minicolumn of yeast (Yamadazyma spartinae) immobilized TiO2 nanoparticles for determination by ICP-AES.

Authors:  Sitki Baytak; Fahmida Zereen; Zikri Arslan
Journal:  Talanta       Date:  2011-01-15       Impact factor: 6.057

3.  The use of rapidly synergistic cloud point extraction for the separation and preconcentration of trace amounts of Ni (II) ions from food and water samples coupling with flame atomic absorption spectrometry determination.

Authors:  Reyhaneh Rahnama; Marzieh Najafi
Journal:  Environ Monit Assess       Date:  2016-02-09       Impact factor: 2.513

4.  Determination of Pb(II), Zn(II), Cd(II), and Co(II) ions by flame atomic absorption spectrometry in food and water samples after preconcentration by coprecipitation with Mo(VI)-diethyldithiocarbamate.

Authors:  Mehmet Tufekci; Volkan Numan Bulut; Hamide Elvan; Duygu Ozdes; Mustafa Soylak; Celal Duran
Journal:  Environ Monit Assess       Date:  2012-04-25       Impact factor: 2.513

5.  Photoreduction of Cr(VI) in water using BiVO4-Fe3O4 nano-photocatalyst under visible light irradiation.

Authors:  Tingling Ke; Hongguang Guo; Yongli Zhang; Yang Liu
Journal:  Environ Sci Pollut Res Int       Date:  2017-10-11       Impact factor: 4.223

6.  Salicylic acid functionalized silica-coated magnetite nanoparticles for solid phase extraction and preconcentration of some heavy metal ions from various real samples.

Authors:  M Reza Shishehbore; Abbas Afkhami; Hasan Bagheri
Journal:  Chem Cent J       Date:  2011-07-15       Impact factor: 4.215

7.  Ultratrace Determination of Cr(VI) and Pb(II) by Microsample Injection System Flame Atomic Spectroscopy in Drinking Water and Treated and Untreated Industrial Effluents.

Authors:  Jameel Ahmed Baig; Tasneem Gul Kazi; Latif Elci; Hassan Imran Afridi; Muhammad Irfan Khan; Hafiz Muhammad Naseer
Journal:  J Anal Methods Chem       Date:  2013-09-18       Impact factor: 2.193

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.