Literature DB >> 17165848

Picomolar peroxide detection using a chemically activated redox mediator and square wave voltammetry.

Jennifer L Lyon1, Keith J Stevenson.   

Abstract

A method for low-level, low-potential electrochemical detection of hydrogen peroxide using a chemically activated redox mediator is presented. This method is unique in that it utilizes a mediator, Amplex Red, which is only redox-active when chemically oxidized by H2O2 in the presence of the enzyme horseradish peroxidase (HRP). When employed in concert with microelectrode square wave voltammetry to optimize sensing at ultralow concentrations (<1 microM), this method exhibits marked improvements in analytical sensitivity and detection limits (limit of detection as low as 8 pM) over existing protocols. Sensing schemes incorporating both freely diffusing and immobilized HRP are evaluated, and the resulting analytical sensitivities are 1.22 +/- 0.04 and (2.1 +/- 0.6) x 10(-1) microA/(microM mm2), respectively, for peroxide concentrations in the high picomolar to low micromolar range. A second linear region exists for lower peroxide concentrations. Furthermore, quantitative enzyme kinetics analysis using Michaelis-Menten parameters is possible through interpretation of data collected in this scheme. Km values for soluble and immobilized HRP were 84 +/- 13 and 504 +/- 19 microM, respectively. This method is amenable to any biological detection scheme that generates hydrogen peroxide as a reactive product.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17165848     DOI: 10.1021/ac061483d

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

Review 1.  Electrochemical sensors.

Authors:  Benjamin J Privett; Jae Ho Shin; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2008-05-21       Impact factor: 6.986

2.  Square-wave voltammetry assays for glycoproteins on nanoporous gold.

Authors:  Binod Pandey; Jay K Bhattarai; Papapida Pornsuriyasak; Kohki Fujikawa; Rosa Catania; Alexei V Demchenko; Keith J Stine
Journal:  J Electroanal Chem (Lausanne)       Date:  2014-03-15       Impact factor: 4.464

3.  A gold electrode modified with a nanoparticulate film composed of a conducting copolymer for ultrasensitive voltammetric sensing of hydrogen peroxide.

Authors:  Rongli Zhang; Can Jiang; Xiaoxia Fan; Renchun Yang; Yanyan Sun; Cuige Zhang
Journal:  Mikrochim Acta       Date:  2017-12-18       Impact factor: 5.833

4.  Nanoporous gold as a solid support for protein immobilization and development of an electrochemical immunoassay for prostate specific antigen and carcinoembryonic antigen.

Authors:  Binod Pandey; Alexei V Demchenko; Keith J Stine
Journal:  Mikrochim Acta       Date:  2012-10-01       Impact factor: 5.833

5.  Generalized platform for antibody detection using the antibody catalyzed water oxidation pathway.

Authors:  M Elizabeth Welch; Nicole L Ritzert; Hongjun Chen; Norah L Smith; Michele E Tague; Youyong Xu; Barbara A Baird; Héctor D Abruña; Christopher K Ober
Journal:  J Am Chem Soc       Date:  2014-01-24       Impact factor: 15.419

6.  Facile Fabrication of a Gold Nanocluster-Based Membrane for the Detection of Hydrogen Peroxide.

Authors:  Pu Zhang; Yi Wang; Yibing Yin
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.