Literature DB >> 17157956

Analysis of a gas-phase partitioning tracer test conducted in an unsaturated fractured-clay formation.

Michelle A Simon1, Mark L Brusseau.   

Abstract

The gas-phase partitioning tracer method was used to estimate non-aqueous phase liquid (NAPL), water, and air saturations in the vadose zone at a chlorinated-solvent contaminated field site in Tucson, AZ. The tracer test was conducted in a fractured-clay system that is the confining layer for the underlying regional aquifer. Three suites of three tracers were injected into wells located 14, 24, and 24 m from a single, central extraction well. The tracers comprised noble gases (traditionally thought to be nonsorbing), alkanes (primarily water partitioning), perfluorides (primarily NAPL partitioning), and halons (both NAPL and water partitioning). Observations of vacuum response were consistent with flow in a fractured system. The halon tracers exhibited the greatest amount of retardation, and helium and the perfluoride tracers the least. The alkane tracers were unexpectedly more retarded than the perfluoride tracers, indicating low NAPL saturations and high water saturations. An NAPL saturation of 0.01, water saturation of 0.215, and gas saturation of 0.775 was estimated based on analysis of the suite of tracers comprising helium, perfluoromethylcyclohexane and dibromodifluoromethane, which was considered to be the most robust set. The estimated saturations compare reasonably well to independently determined values.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17157956     DOI: 10.1016/j.jconhyd.2006.09.010

Source DB:  PubMed          Journal:  J Contam Hydrol        ISSN: 0169-7722            Impact factor:   3.188


  4 in total

1.  Impact of in situ chemical oxidation on contaminant mass discharge: linking source-zone and plume-scale characterizations of remediation performance.

Authors:  M L Brusseau; K C Carroll; T Allen; J Baker; W Diguiseppi; J Hatton; C Morrison; A Russo; J Berkompas
Journal:  Environ Sci Technol       Date:  2011-05-26       Impact factor: 9.028

2.  Assessing the impact of source-zone remediation efforts at the contaminant-plume scale through analysis of contaminant mass discharge.

Authors:  M L Brusseau; J Hatton; W DiGuiseppi
Journal:  J Contam Hydrol       Date:  2011-08-26       Impact factor: 3.188

3.  Characterization and Remediation of Chlorinated Volatile Organic Contaminants in the Vadose Zone: An Overview of Issues and Approaches.

Authors:  Mark L Brusseau; Kenneth C Carroll; Michael J Truex; David J Becker
Journal:  Vadose Zone J       Date:  2013-11-01       Impact factor: 3.289

4.  Vapor-phase transport of trichloroethene in an intermediate-scale vadose-zone system: retention processes and tracer-based prediction.

Authors:  Molly S Costanza-Robinson; Tyson D Carlson; Mark L Brusseau
Journal:  J Contam Hydrol       Date:  2012-12-22       Impact factor: 3.188

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.