Effect of continuous arterial blood flow in patients with rotary cardiac assist device on the washout of a stenosis wake in the carotid bifurcation: a computer simulation study.

Martin Prosi1, Karl Perktold, Heinrich Schima.   

Abstract

In recipients of rotary blood pumps for cardiac assist, the pulsatility of arterial flow is considerably diminished. This influences the shear stress patterns and streamlines in the arterial bed, with potential influence on washout and plaque growth. These effects may be aggravated in the recirculation area of stenoses, and therefore, exclude patients with atherosclerosis from the therapy with these devices. A numerical study was performed for the human carotid artery bifurcation with the assumption of a massive stenosis (75% reduction of cross-section area) in the carotid bulb. Four different flow time patterns (no support to full pump support) were applied. Flow patterns and particle residence time within the recirculation region were calculated, once within the relevant volume behind the stenosis and and once within a small region directly at the posterior heel of the stenosis. The flow patterns showed a considerable radial vorticity behind the stenosis. Mean particle residence time in the whole recirculation region was 15% less for high pump support (nearly continuous flow) compared to the natural flow pattern (0.19s compared to 0.22s), and nearly identical for the small heel region (0.28 to 0.27s). The flow simulation demonstrates, that even in the case of a pre-existing stenosis, the local effects of continuous flow on particle residence times are rather minimal (as was shown previously for intact arterial geometries). Therefore, from the point of macroscopic flow field analysis, continuous flow should not enhance the thromboembolic risk in ventricular assist device recipients.

Entities:  

Mesh:

Year:  2006        PMID: 17157302     DOI: 10.1016/j.jbiomech.2006.10.017

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  Two Automated Techniques for Carotid Lumen Diameter Measurement: Regional versus Boundary Approaches.

Authors:  Tadashi Araki; P Krishna Kumar; Harman S Suri; Nobutaka Ikeda; Ajay Gupta; Luca Saba; Jeny Rajan; Francesco Lavra; Aditya M Sharma; Shoaib Shafique; Andrew Nicolaides; John R Laird; Jasjit S Suri
Journal:  J Med Syst       Date:  2016-06-14       Impact factor: 4.460

2.  Computational fluid dynamics-based study of possibility of generating pulsatile blood flow via a continuous-flow VAD.

Authors:  Erfan Nammakie; Hanieh Niroomand-Oscuii; Mojtaba Koochaki; Farzan Ghalichi
Journal:  Med Biol Eng Comput       Date:  2016-05-27       Impact factor: 2.602

Review 3.  Lagrangian postprocessing of computational hemodynamics.

Authors:  Shawn C Shadden; Amirhossein Arzani
Journal:  Ann Biomed Eng       Date:  2014-07-25       Impact factor: 3.934

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.