Literature DB >> 17153982

Morphological evaluation of 2- and 1-step self-etching system interfaces with dentin.

Ivana Radovic1, Zoran R Vulicevic, Franklin García-Godoy.   

Abstract

This in vitro study evaluated the resin-dentin interface formed by two 2-step and two 1-step self-etching adhesive systems under SEM. Class V cavities (4 x 2.5 x 1.5 mm) were prepared on the buccal surfaces of 25 extracted intact human third molars using a carbide bur in a high-speed handpiece. Four self-etching systems with corresponding resins were used: two 2-step systems, AdheSE (Ivoclar Vivadent) and Contax (DMG Hamburg), one 1-step/2 components system Futurabond NR (Voco) and a 1-step/1 component adhesive G-Bond (GC Corp). An etch and rinse system, PQ Clear (Ultradent), was used as a control. The teeth were thermocycled (500 cycles, 5 degrees /55 degrees C, 30 seconds dwell time), and 2 sections were made longitudinally through the restorations with a low-speed diamond saw, producing approximately 1-mm wide samples. The samples were polished with silicon carbide paper of increasing grit (400-1000), demineralized (6N HCl, 30 seconds), deproteinized (2.5% NaOC1, 10 minutes), left to air dry for 24 hours in a desiccator under low vacuum pressure, gold sputtered and viewed under SEM (JEOL-JSM-6460LV). In the AdheSE, Contax and Futurabond NR specimens, resin tag penetration into the tubules and lateral tags could be seen. G-Bond showed different interface morphology, with a tight, thin continuous junction and almost no resin penetration into tubules. PQ Clear samples exhibited the highest number of resin tags with numerous lateral tags. A clearly defined hybrid layer was seen in the Contax and PQ Clear specimens. Investigated self-etching systems showed similar interfacial morphology with dentin, except for the 1 step/1 component adhesive G-Bond. The degree of demineralization and interaction with dentin correlated with the acidity of the self-etching primers/adhesives. Fewer resin tags were formed with self-etching primers/adhesives than with the etch and rinse system.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17153982     DOI: 10.2341/05-145

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  12 in total

1.  TiF4 improves microtensile bond strength to dentin when using an adhesive system regardless of primer/bond application timing and method.

Authors:  Juliana Bomfigli Tranquilin; Enrico Coser Bridi; Flávia Lucisano Botelho Amaral; Fabiana Mantovani Gomes França; Cecilia Pedroso Turssi; Roberta Tarkany Basting
Journal:  Clin Oral Investig       Date:  2015-05-31       Impact factor: 3.573

2.  Effect of hybrid layer and thickness on stress distribution of cervical wedge-shaped restorations.

Authors:  Evrim Eliguzeloglu; Oguz Eraslan; Huma Omurlu; Gurcan Eskitascıoglu; Sema Belli
Journal:  Eur J Dent       Date:  2010-04

3.  Enzymatic biodegradation of HEMA/bisGMA adhesives formulated with different water content.

Authors:  Elisabet L Kostoryz; Kiran Dharmala; Qiang Ye; Yong Wang; Jesse Huber; Jong-Gu Park; Grant Snider; J Lawrence Katz; Paulette Spencer
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2009-02       Impact factor: 3.368

4.  Comparative evaluation of microleakage of fifth, sixth, and seventh generation dentin bonding agents: An in vitro study.

Authors:  S Vinay; Vasundhara Shivanna
Journal:  J Conserv Dent       Date:  2010-07

5.  In vitro bonding effectiveness of self-etch adhesives with different application techniques: A microleakage and scanning electron microscopic study.

Authors:  Rajni Nagpal; Naveen Manuja; Shashi Prabha Tyagi; Udai Pratap Singh
Journal:  J Conserv Dent       Date:  2011-07

6.  Morphological evaluation of new total etching and self etching adhesive system interfaces with dentin.

Authors:  Mithra N Hegde; Priyadarshini Hegde; C Ravi Chandra
Journal:  J Conserv Dent       Date:  2012-04

7.  Does the use of a novel self-adhesive flowable composite reduce nanoleakage?

Authors:  Abeer Abo El Naga; Mohammed Yousef; Rasha Ramadan; Sherif Fayez Bahgat; Lana Alshawwa
Journal:  Clin Cosmet Investig Dent       Date:  2015-03-27

8.  Nanotechnology in Dentin Disinfection: Can We Preserve the Bond?

Authors:  Prabhakar A Ramasetty; Amrita P Tripathi; Sugandhan S; Saraswathi V Naik; Deepak Bm
Journal:  Int J Clin Pediatr Dent       Date:  2018 Nov-Dec

9.  Shear bond strengths and morphological evaluation of filled and unfilled adhesive interfaces to enamel and dentine.

Authors:  Vajihesadat Mortazavi; Mohammadhosein Fathi; Ebrahim Ataei; Niloufar Khodaeian; Navid Askari
Journal:  Int J Dent       Date:  2012-11-06

10.  Nanotechnology in Dentin Disinfection: Can We Preserve the Bond?

Authors:  Prabhakar Attiguppe; Amrita P Tripathi; Suriyan Sugandhan; Saraswathi V Naik; Bikshavathi M Deepak
Journal:  Int J Clin Pediatr Dent       Date:  2019 Jan-Feb
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.