Literature DB >> 17153416

Accurate calibration of a stereo-vision system in image-guided radiotherapy.

Dezhi Liu1, Shidong Li.   

Abstract

Image-guided radiotherapy using a three-dimensional (3D) camera as the on-board surface imaging system requires precise and accurate registration of the 3D surface images in the treatment machine coordinate system. Two simple calibration methods, an analytical solution as three-point matching and a least-squares estimation method as multipoint registration, were introduced to correlate the stereo-vision surface imaging frame with the machine coordinate system. Both types of calibrations utilized 3D surface images of a calibration template placed on the top of the treatment couch. Image transformational parameters were derived from corresponding 3D marked points on the surface images to their given coordinates in the treatment room coordinate system. Our experimental results demonstrated that both methods had provided the desired calibration accuracy of 0.5 mm. The multipoint registration method is more robust particularly for noisy 3D surface images. Both calibration methods have been used as our weekly QA tools for a 3D image-guided radiotherapy system.

Mesh:

Year:  2006        PMID: 17153416     DOI: 10.1118/1.2362873

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Clinical results of a pilot study on stereovision-guided stereotactic radiotherapy and intensity modulated radiotherapy.

Authors:  Shidong Li; Lawrence R Kleinberg; Daniele Rigamonti; Moody D Wharam; Abdul Rashid; Juan Jackson; David Djajaputra; Shenjen He; Tunisia Creasey; Theodore L DeWeese
Journal:  Technol Cancer Res Treat       Date:  2010-12

2.  Initial validation and clinical experience with 3D optical-surface-guided whole breast irradiation of breast cancer.

Authors:  S Li; T DeWeese; B Movsas; Dezhi Liu; Deborah Frassica; Jinkoo Kim; Qing Chen; Eleanor Walker
Journal:  Technol Cancer Res Treat       Date:  2012-02

3.  Surface imaging-based analysis of intrafraction motion for breast radiotherapy patients.

Authors:  David B Wiant; Stacy Wentworth; Jacqueline M Maurer; Caroline L Vanderstraeten; Jonathon A Terrell; Benjamin J Sintay
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

4.  A novel method for radiotherapy patient identification using surface imaging.

Authors:  David B Wiant; Quinton Verchick; Percy Gates; Caroline L Vanderstraeten; Jacqueline M Maurer; T Lane Hayes; Han Liu; Benjamin J Sintay
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.