Literature DB >> 17153385

Characteristic features of a high-energy x-ray spectra estimation method based on the Waggener iterative perturbation principle.

Akira Iwasaki1, Mamoru Kubota, Junichi Hirota, Akira Fujimori, Katsumasa Suzaki, Masahiko Aoki, Yoshinao Abe.   

Abstract

We have redeveloped a high-energy x-ray spectra estimation method reported by Iwasaki et al. [A. Iwasaki, H. Matsutani, M. Kubota, A. Fujimori, K. Suzaki, and Y. Abe, Radiat. Phys. Chem. 67, 81-91 (2003)]. The method is based on the iterative perturbation principle to minimize differences between measured and calculated transmission curves, originally proposed by Waggener et al. [R. G. Waggener, M. M. Blough, J. A. Terry, D. Chen, N. E. Lee, S. Zhang, and W. D. McDavid, Med. Phys. 26, 1269-1278 (1999)]. The method can estimate spectra applicable for media at least from water to lead using only about ten energy bins. Estimating spectra of 4-15 MV x-ray beams from a linear accelerator, we describe characteristic features of the method with regard to parameters including the prespectrum, number of transmission measurements, number of energy bins, energy bin widths, and artifactual bipeaked spectrum production.

Entities:  

Mesh:

Year:  2006        PMID: 17153385     DOI: 10.1118/1.2359227

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Reconsideration of the Iwasaki-Waggener iterative perturbation method for reconstructing high-energy X-ray spectra.

Authors:  Akira Iwasaki; Shigenobu Kimura; Kohji Sutoh; Kazuo Kamimura; Makoto Sasamori; Morio Seino; Fumio Komai; Singo Terashima; Mamoru Kubota; Yuichiro Narita; Yoichiro Hosokawa; Masanori Miyazawa
Journal:  Radiol Phys Technol       Date:  2012-06-14

2.  Determination of radiotherapy X-ray spectra using a screen-film system.

Authors:  H M Garnica-Garza
Journal:  Med Biol Eng Comput       Date:  2008-09-09       Impact factor: 2.602

3.  A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: comparison of calculated and measured 10-MV X-ray doses in thorax-like phantoms.

Authors:  Shigenobu Kimura; Kohji Sutoh; Kazuo Kamimura; Akira Iwasaki; Makoto Sasamori; Fumio Komai; Morio Seino; Singo Terashima; Mamoru Kubota; Junichi Hirota; Yoichiro Hosokawa
Journal:  Radiol Phys Technol       Date:  2011-06-22

4.  A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: a theoretical study on 10-MV X-ray dose calculations in thorax-like phantoms.

Authors:  Akira Iwasaki; Shigenobu Kimura; Kohji Sutoh; Kazuo Kamimura; Makoto Sasamori; Fumio Komai; Morio Seino; Singo Terashima; Mamoru Kubota; Junichi Hirota; Yoichiro Hosokawa
Journal:  Radiol Phys Technol       Date:  2011-06-15

5.  CT scanner x-ray spectrum estimation from transmission measurements.

Authors:  Xinhui Duan; Jia Wang; Lifeng Yu; Shuai Leng; Cynthia H McCollough
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.