Literature DB >> 17153377

Updated Solid Water to water conversion factors for 125I and l03Pd brachytherapy sources.

Ali S Meigooni1, Shahid B Awan, Nathan S Thompson, Sharifeh A Dini.   

Abstract

Dosimetric characteristics of brachytherapy sources are normally determined in water using a Monte Carlo simulation technique and in water equivalent phantom material using both experimental and Monte Carlo simulation techniques. The consensuses of these results are then calculated for clinical applications by converting experimental data obtained in water equivalent material to water using a conversion factor. These conversion factors are normally determined as a ratio of the Monte Carlo-simulated dose rate constant in liquid water to the dose rate constant in a water-equivalent phantom material. However, it has been noted that conversion factors utilized by some investigators have been derived using incorrect phantom material composition and incorrect cross-sectional data information. The impact of errors associated with the cross-sectional data and chemical composition of the phantom material used in dosimetric evaluation of brachytherapy sources has been investigated in this project. Results of these investigations have shown that the use of Solid Water with 1.7% calcium content, as compared to the 2.3% value stated by the manufacturer, may lead to 5% and 9% differences in conversion factors for 125I and 103Pd, respectively.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17153377     DOI: 10.1118/1.2357018

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Ice as a water-equivalent solid medium for brachytherapy dosimetric measurements.

Authors:  Haijun Song; Zhe Chen; Ning Yue; Qingrong Wu; Fang-Fang Yin
Journal:  Radiat Environ Biophys       Date:  2008-12-09       Impact factor: 1.925

2.  A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: report of AAPM Task Group No. 138 and GEC-ESTRO.

Authors:  Larry A DeWerd; Geoffrey S Ibbott; Ali S Meigooni; Michael G Mitch; Mark J Rivard; Kurt E Stump; Bruce R Thomadsen; Jack L M Venselaar
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

3.  Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source.

Authors:  Regina K Fulkerson; John A Micka; Larry A DeWerd
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

4.  Dosimetric effect of tissue heterogeneity for (125)I prostate implants.

Authors:  Susana Maria Oliveira; Nuno José Teixeira; Lisete Fernandes; Pedro Teles; Pedro Vaz
Journal:  Rep Pract Oncol Radiother       Date:  2014-04-16

5.  Monte Carlo modeling of Co HDR brachytherapy source in water and in different solid water phantom materials.

Authors:  S Sahoo; T Palani Selvam; R S Vishwakarma; G Chourasiya
Journal:  J Med Phys       Date:  2010-01

6.  Monte Carlo-based investigation of water-equivalence of solid phantoms at (137)Cs energy.

Authors:  Ramkrushna S Vishwakarma; T Palani Selvam; Sridhar Sahoo; Subhalaxmi Mishra; Ghanshyam Chourasiya
Journal:  J Med Phys       Date:  2013-10

7.  Dosimetric characterization of GMS BT-125-1 125 I radioactive seed with Monte Carlo simulations and experimental measurement.

Authors:  Nan Zhao; Ruijie Yang; Li Ren; Yi Fan; Junli Li; Jianguo Zhang
Journal:  J Appl Clin Med Phys       Date:  2017-09-14       Impact factor: 2.102

  7 in total