Literature DB >> 17152784

Perimount pericardial bioprosthesis for aortic calcified stenosis: 18-year experience with 1133 patients.

Michel R Aupart1, Alain Mirza, Yvon A Meurisse, Agnes L Sirinelli, Paul H Neville, Michel A Marchand.   

Abstract

BACKGROUND AND AIM OF THE STUDY: Aortic stenosis (AS) is the most important cause of aortic valve disease, its prevalence increasing with patient age. The present study formed part of a long-term evaluation on use of the Perimount pericardial valve for aortic calcified stenosis.
METHODS: A total of 1133 consecutive patients who underwent aortic valve replacement (AVR) with a Perimount pericardial bioprosthesis for degenerative AS between July 1984 and December 2003 at the authors' institution, was followed up in 2004. Among the patients (716 males, 417 females; mean age 72.6 years), 997 were in sinus rhythm, and the mean NYHA functional class was 2.3. Preoperative echocardiography indicated a mean gradient of 56 mmHg, a peak gradient of 89 mmHg, and an effective orifice area of 0.6 cm2. Associated procedures were required in 336 patients.
RESULTS: All patients but 18 (1.5%) were followed up for an average of 5.5 years postoperatively; thus, the total follow up was 6,180 patient-years. Operative mortality was 2.8% (n=32), and there were 330 late deaths. At 18 years the actuarial survival rate was 22 +/- 4%. Among the 725 patients followed, 80% were in sinus rhythm and 98% in NYHA classes I or II. Valve-related complications included 39 thromboembolic episodes, 24 endocarditis, 22 anticoagulant-related hemorrhage, 28 reoperations, and 19 structural valve failures. A total of 54 patients died from valve-related causes (13 embolic events, two endocarditis, two hemorrhage, one structural failure, 36 unknown causes), and 57 died from cardiac failure. Neither thrombosis nor hemolysis was observed. At 18 years, freedom from embolism was 92 +/- 2%, from endocarditis 93 +/- 4%, from hemorrhage 95 +/- 2%, from reoperation 62 +/- 11%, from valve failure 68 +/- 12%, and from all complications 47 +/- 8%. Among patients aged >60 years, the 18-year actuarial freedom from reoperation was 76 +/- 14%, and from valve failure 85 +/- 8%.
CONCLUSION: With a low rate of valve-related events at 18 years, and an especially low rate of structural failure, the Perimount pericardial prosthesis is a reliable choice for patients with aortic calcified stenosis.

Entities:  

Mesh:

Year:  2006        PMID: 17152784

Source DB:  PubMed          Journal:  J Heart Valve Dis        ISSN: 0966-8519


  7 in total

1.  Noninferiority of Shanghai Cingular biotech's bovine pericardial valve preclinical study in juvenile ovine model.

Authors:  Jin-Miao Chen; Yu Ding; Shu-Yang Lu; Sun Pan; Mieradilijiang Abudupataer; Tao Hong; Chun-Sheng Wang
Journal:  J Thorac Dis       Date:  2016-06       Impact factor: 2.895

2.  Triple-valve treatment for prosthetic valve endocarditis occurring 20 years after implantation of a Carpentier-Edwards pericardial bioprosthesis in the aortic valve.

Authors:  Yoichi Hisata; Shiro Hazama; Kenta Izumi; Kiyoyuki Eishi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2008-12-16

3.  Choice of Aortic Valve Prosthesis in a Rapidly Aging and Long-Living Society.

Authors:  Yoshimasa Sakamoto; Michio Yoshitake; Yoko Matsumura; Hitomi Naruse; Ko Bando; Kazuhiro Hashimoto
Journal:  Ann Thorac Cardiovasc Surg       Date:  2016-09-12       Impact factor: 1.520

4.  Durability of bioprosthetic cardiac valves.

Authors:  Grischa Hoffmann; Georg Lutter; Jochen Cremer
Journal:  Dtsch Arztebl Int       Date:  2008-02-22       Impact factor: 5.594

Review 5.  Stentless aortic valve replacement: an update.

Authors:  Junjiro Kobayashi
Journal:  Vasc Health Risk Manag       Date:  2011-06-02

6.  Antithrombotic Strategies After Bioprosthetic Aortic Valve Replacement: A Systematic Review.

Authors:  Joel N Papak; Joseph C Chiovaro; North Noelck; Laura D Healy; Michele Freeman; Jacquelyn A Quin; Robin Paynter; Allison Low; Karli Kondo; Owen J T McCarty; Devan Kansagara
Journal:  Ann Thorac Surg       Date:  2018-11-17       Impact factor: 4.330

7.  Prognosis after surgical replacement with a bioprosthetic aortic valve in patients with severe symptomatic aortic stenosis: systematic review of observational studies.

Authors:  Farid Foroutan; Gordon H Guyatt; Kathleen O'Brien; Eva Bain; Madeleine Stein; Sai Bhagra; Daegan Sit; Rakhshan Kamran; Yaping Chang; Tahira Devji; Hassan Mir; Veena Manja; Toni Schofield; Reed A Siemieniuk; Thomas Agoritsas; Rodrigo Bagur; Catherine M Otto; Per O Vandvik
Journal:  BMJ       Date:  2016-09-28
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.