Literature DB >> 17151966

Aortic valve replacement and coronary artery surgery: determinants affecting early and long-term results.

P Stassano1, L Di Tommaso, D F Vitale, M Monaco, G Iannelli, M Mottola, A Musumeci, N Spampinato.   

Abstract

BACKGROUND: We studied factors influencing early and late results in patients operated on for aortic valve replacement and coronary artery bypass graft.
METHODS: 175 patients were retrospectively analysed over a 10-year period ending in December 2002. There were 135 males and 40 females with a mean age of 62.7 +/- 8.9 years; 109 were in NYHA class III/IV; 45 required an urgent operation, and 103 mechanical valves and 72 biological valves were implanted.
RESULTS: There were 11 operative deaths (6.3 %). Statistical analysis (logistic regression) showed that previous myocardial infarction, poor NYHA class, and low LVEF had a significant effect on early death. There were 52 late deaths at a mean follow-up of 82.7 +/- 38.8 months. Using a Cox survival analysis for any causes, age, urgent operation, low LVEF, and creatinine had a strong impact on unfavourable late outcome.
CONCLUSIONS: A combination of a patient-related factor (age), cardiac-related condition (low LVEF), co-morbid condition (renal dysfunction), and operative cause (urgent operation) is the most important predictor of late clinical outcome for this combined surgical procedure.

Entities:  

Mesh:

Year:  2006        PMID: 17151966     DOI: 10.1055/s-2006-924467

Source DB:  PubMed          Journal:  Thorac Cardiovasc Surg        ISSN: 0171-6425            Impact factor:   1.827


  4 in total

Review 1.  One problem two issues! Left ventricular systolic and diastolic dysfunction in aortic stenosis.

Authors:  Maqsood M Elahi; Anthony Chuang; Michael J Ewing; Charles H Choi; Peter W Grant; Bashir M Matata
Journal:  Ann Transl Med       Date:  2014-01

2.  Durability of bioprosthetic cardiac valves.

Authors:  Grischa Hoffmann; Georg Lutter; Jochen Cremer
Journal:  Dtsch Arztebl Int       Date:  2008-02-22       Impact factor: 5.594

3.  Adenosine stress first pass perfusion for the detection of coronary artery disease in patients with aortic stenosis: a feasibility study.

Authors:  Christof Burgstahler; Markus Kunze; Meinrad P Gawaz; Volker Rasche; Jochen Wöhrle; Vinzenz Hombach; Nico Merkle
Journal:  Int J Cardiovasc Imaging       Date:  2007-05-31       Impact factor: 2.357

4.  Prognosis after surgical replacement with a bioprosthetic aortic valve in patients with severe symptomatic aortic stenosis: systematic review of observational studies.

Authors:  Farid Foroutan; Gordon H Guyatt; Kathleen O'Brien; Eva Bain; Madeleine Stein; Sai Bhagra; Daegan Sit; Rakhshan Kamran; Yaping Chang; Tahira Devji; Hassan Mir; Veena Manja; Toni Schofield; Reed A Siemieniuk; Thomas Agoritsas; Rodrigo Bagur; Catherine M Otto; Per O Vandvik
Journal:  BMJ       Date:  2016-09-28
  4 in total