Literature DB >> 17149646

Arthroscopic hybrid double-row rotator cuff repair.

Kyung-Cheon Kim1, Kwang-Jin Rhee, Hyun-Dae Shin, Young-Mo Kim.   

Abstract

A Beath pin is drilled on the greater tuberosity under arthroscopy using an anterior cruciate ligament guide. The suture anchor is inserted in the lateral aspect of the footprint. Sutures are then passed through the margins of the rotator cuff tear and tied with sliding knot. One strand of tied suture anchor is passed into the bony trough. One passed strand and the other strand are then tied with a non-sliding knot on the greater tuberosity. The strength of cuff fixation does not only rely on the quality of the bone, it restores the footprint contact area of rotator cuff, and reduces the use of suture anchors to the minimum in this method.

Entities:  

Mesh:

Year:  2006        PMID: 17149646     DOI: 10.1007/s00167-006-0230-7

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.114


  8 in total

1.  Knot security in simple sliding knots and its relationship to rotator cuff repair: how secure must the knot be?

Authors:  S S Burkhart; M A Wirth; M Simonich; D Salem; D Lanctot; K Athanasiou
Journal:  Arthroscopy       Date:  2000-03       Impact factor: 4.772

2.  Rotator cuff tears: the effect of the reconstruction method on three-dimensional repair site area.

Authors:  Maria Apreleva; Mehmet Ozbaydar; Peter G Fitzgibbons; Jon J P Warner
Journal:  Arthroscopy       Date:  2002 May-Jun       Impact factor: 4.772

3.  Sutures and suture anchors: update 2003.

Authors:  F Alan Barber; Morley A Herbert; David P Richards
Journal:  Arthroscopy       Date:  2003-11       Impact factor: 4.772

4.  Double-row arthroscopic rotator cuff repair: re-establishing the footprint of the rotator cuff.

Authors:  Ian K Y Lo; Stephen S Burkhart
Journal:  Arthroscopy       Date:  2003-11       Impact factor: 4.772

5.  Loop security as a determinant of tissue fixation security.

Authors:  S S Burkhart; M A Wirth; M Simonick; D Salem; D Lanctot; K Athanasiou
Journal:  Arthroscopy       Date:  1998-10       Impact factor: 4.772

6.  Complications of metallic suture anchors in shoulder surgery: A report of 8 cases.

Authors:  T K Kaar; R C Schenck; M A Wirth; C A Rockwood
Journal:  Arthroscopy       Date:  2001-01       Impact factor: 4.772

7.  Complications about the glenohumeral joint related to the use of screws and staples.

Authors:  J D Zuckerman; F A Matsen
Journal:  J Bone Joint Surg Am       Date:  1984-02       Impact factor: 5.284

8.  Mini-open rotator cuff repair using a two-row fixation technique: outcomes analysis in patients with small, moderate, and large rotator cuff tears.

Authors:  Stephen Fealy; T Peter Kingham; David W Altchek
Journal:  Arthroscopy       Date:  2002 Jul-Aug       Impact factor: 4.772

  8 in total
  3 in total

Review 1.  Single versus double-row repair of the rotator cuff: does double-row repair with improved anatomical and biomechanical characteristics lead to better clinical outcome?

Authors:  Stephan Pauly; Christian Gerhardt; Jianhai Chen; Markus Scheibel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-08-25       Impact factor: 4.342

Review 2.  Arthroscopic fixation for a malunited greater tuberosity fracture using the suture-bridge technique: technical report and literature review.

Authors:  Jong-Hun Ji; Chang-Yun Moon; Young-Yul Kim; Mohamed Shafi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-04-28       Impact factor: 4.342

Review 3.  Soft tissue tenodesis of the long head of the biceps tendon associated to the Roman Bridge repair.

Authors:  Francesco Franceschi; Umile Giuseppe Longo; Laura Ruzzini; Giacomo Rizzello; Nicola Maffulli; Vincenzo Denaro
Journal:  BMC Musculoskelet Disord       Date:  2008-06-04       Impact factor: 2.362

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.