Literature DB >> 17143719

Whole-body three-dimensional contrast-enhanced magnetic resonance (MR) angiography with parallel imaging techniques on a multichannel MR system for the detection of various systemic arterial diseases.

Jiang Lin1, Bin Chen, Jian-Hua Wang, Meng-Su Zeng, Yi-Xiang Wang.   

Abstract

Using a 1.5-T magnetic resonance (MR) imager equipped with 32 receiving channels and integrated parallel acquisition techniques, 37 patients underwent whole-body three-dimensional (3D) contrast-enhanced MR angiography (WB 3D CE MRA). The patients included had clinically documented or suspected peripheral arterial occlusive disease (PAOD, n = 19), Takayasu arteritis (n = 8), polyarteritis nodosa (n = 1), type-B dissection (n = 4), thoracic and/or abdominal aneurysm (n = 5). Sixty-eight surface coils were employed to encompass the whole body. Four 3D CE MRA stations were acquired successively through automatic table moving. The spatial resolution was 1.6 x 1.0 mm and slice thickness was 1.5 mm for all stations. A total scan range of 188 cm was acquired. Overall image quality of each arterial segment and venous overlay were assessed. The depiction of various systemic arterial diseases was evaluated and compared, in 20 patients, with other imaging modalities. This WB 3D CE MRA yielded a detailed display of the arterial system with an average MR room time of 17.4 min. The image quality was considered diagnostic in 99.3% of the arterial segments. In 7 of 19 patients with PAOD, WB MRA showed additional vascular narrowing apart from peripheral arterial disease. In nine patients with vasculitis, WB MRA depicted luminal irregularity, narrowing or occlusion, aneurysm, and collateral circulation involving multiple vascular segments. WB MRA also clearly revealed the severity and extent of dissection and aortic aneurysm. In 20 cases where additional imaging investigations have been carried out, the vascular pathologies demonstrated by WB MRA agree with these additional imaging investigations.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17143719     DOI: 10.1007/s00380-006-0918-0

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  12 in total

1.  Detection of atherosclerosis: systemic imaging for systemic disease with whole-body three-dimensional MR angiography--initial experience.

Authors:  Mathias Goyen; Christoph U Herborn; Knut Kröger; Thomas C Lauenstein; Jörg F Debatin; Stefan G Ruehm
Journal:  Radiology       Date:  2003-02-19       Impact factor: 11.105

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  Whole-body three-dimensional MR angiography with a rolling table platform: initial clinical experience.

Authors:  Mathias Goyen; Harald H Quick; Jörg F Debatin; Mark E Ladd; Jörg Barkhausen; Christoph U Herborn; Silke Bosk; Hilmar Kuehl; Michael Schlepütz; Stefan G Ruehm
Journal:  Radiology       Date:  2002-07       Impact factor: 11.105

Review 4.  MR angiography of the chest.

Authors:  Florian M Vogt; Mathias Goyen; Jörg F Debatin
Journal:  Radiol Clin North Am       Date:  2003-01       Impact factor: 2.303

Review 5.  MR angiography of the abdominal aorta and peripheral vessels.

Authors:  Vincent B Ho; William R Corse
Journal:  Radiol Clin North Am       Date:  2003-01       Impact factor: 2.303

6.  Cardiovascular screening with parallel imaging techniques and a whole-body MR imager.

Authors:  Harald Kramer; Stefan O Schoenberg; Konstantin Nikolaou; Armin Huber; Anja Struwe; Eva Winnik; Bernd J Wintersperger; Olaf Dietrich; Berthold Kiefer; Maximilian F Reiser
Journal:  Radiology       Date:  2005-07       Impact factor: 11.105

7.  Total-body 3D magnetic resonance angiography influences the management of patients with peripheral arterial occlusive disease.

Authors:  Mathias Goyen; Christoph U Herborn; Knut Kröger; Stefan G Ruehm; Jörg F Debatin
Journal:  Eur Radiol       Date:  2005-09-21       Impact factor: 5.315

8.  Whole-body MR angiography using a novel 32-receiving-channel MR system with surface coil technology: first clinical experience.

Authors:  Michael Fenchel; Martin Requardt; Katrin Tomaschko; Ulrich Kramer; Norbert I Stauder; Thomas Naegele; Heinz-Peter Schlemmer; Claus D Claussen; Stephan Miller
Journal:  J Magn Reson Imaging       Date:  2005-05       Impact factor: 4.813

9.  Rapid magnetic resonance angiography for detection of atherosclerosis.

Authors:  S G Ruehm; M Goyen; J Barkhausen; K Kröger; S Bosk; M E Ladd; J F Debatin
Journal:  Lancet       Date:  2001-04-07       Impact factor: 79.321

10.  Whole-body 3D MR angiography of patients with peripheral arterial occlusive disease.

Authors:  Christoph U Herborn; Mathias Goyen; Harald H Quick; Silke Bosk; Sandra Massing; Knut Kroeger; Dirk Stoesser; Stefan G Ruehm; Jörg F Debatin
Journal:  AJR Am J Roentgenol       Date:  2004-06       Impact factor: 3.959

View more
  13 in total

1.  Value of whole-body contrast-enhanced magnetic resonance angiography with vessel wall imaging in quantitative assessment of disease activity and follow-up examination in Takayasu's arteritis.

Authors:  Ying Sun; Lili Ma; Zongfei Ji; Zhuojun Zhang; Huiyong Chen; Hao Liu; Yan Shan; Fuhua Yan; Lindi Jiang
Journal:  Clin Rheumatol       Date:  2015-02-11       Impact factor: 2.980

Review 2.  Parallel magnetic resonance imaging.

Authors:  Ulrich Katscher; Peter Börnert
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

Review 3.  Imaging studies in the diagnosis and management of vasculitis.

Authors:  Luis M Amezcua-Guerra; Carlos Pineda
Journal:  Curr Rheumatol Rep       Date:  2007-08       Impact factor: 4.592

4.  Stenting for superficial femoral artery atherosclerotic occlusion: long-term follow-up results.

Authors:  Yoshio Sasaki; Myung-Woo Hwang; Kuniyuki Shirasawa; Shinichi Takeda; Hiroyuki Ayukawa; Katsura Inenaga-Kitaura; Rei Takeoka; Yasushi Kitaura; Chuichi Kawai
Journal:  Heart Vessels       Date:  2008-07-23       Impact factor: 2.037

Review 5.  Whole-Body MRA.

Authors:  Harald Kramer; Harald H Quick; Bernd Tombach; Stefan O Schoenberg; Joerg Barkhausen
Journal:  Eur Radiol       Date:  2008-05-20       Impact factor: 5.315

6.  Childhood polyarteritis nodosa: diagnosis with non-invasive imaging techniques.

Authors:  Z Birsin Özçakar; Suat Fitöz; Adalet Elçin Yıldız; Fatoş Yalçınkaya
Journal:  Clin Rheumatol       Date:  2016-10-05       Impact factor: 2.980

7.  The K121Q polymorphism of ENPP1 and peripheral arterial disease.

Authors:  Philipp Eller; Wilfried Schgoer; Thomas Mueller; Ivan Tancevski; Egon Demetz; Kristina Duwensee; Andreas Ritsch; Meinhard Haltmayer; Josef R Patsch
Journal:  Heart Vessels       Date:  2008-04-04       Impact factor: 2.037

8.  A total atherosclerotic score for whole-body MRA and its relation to traditional cardiovascular risk factors.

Authors:  T Hansen; H Ahlström; J Wikström; L Lind; L Johansson
Journal:  Eur Radiol       Date:  2008-02-13       Impact factor: 5.315

Review 9.  A case of concentric left ventricular hypertrophy with falsely normal blood pressure in patient with Takayasu's arteritis.

Authors:  Il-Suk Sohn; Suk-Tae Jang; Eun-Sun Jin; Sung-Min Park; Jin-Man Cho; Young-Tae Kwak; Chong-Jin Kim; Hochul Park; Jong-Hoa Bae
Journal:  Heart Vessels       Date:  2008-05-17       Impact factor: 2.037

10.  Comparison between a linear versus a macrocyclic contrast agent for whole body MR angiography in a clinical routine setting.

Authors:  Achim Seeger; Ulrich Kramer; Michael Fenchel; Florian Grimm; Christiane Bretschneider; Jörg Döring; Bernhard Klumpp; Gunnar Tepe; Kilian Rittig; Peter R Seidensticker; Claus D Claussen; Stephan Miller
Journal:  J Cardiovasc Magn Reson       Date:  2008-12-30       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.