Literature DB >> 17134670

Effects of neurosurgical titanium mesh on radiation dose.

Hassisen Patone1, Jennifer Barker, David Roberge.   

Abstract

The purpose of this study was to determine the dosimetric impact of a neurosurgical titanium mesh in patients treated with 6- and 18-MV photon beams. The effects of a 0.4-mm-thick titanium mesh on the dose profile at 3 regions within a solid water phantom were measured using extended dose range-2 (EDR2) film for 6- and 18-MV photon beams. All measurements were performed with the titanium mesh placed at a depth of 1.5 cm in the phantom. Films were exposed immediately above the mesh, immediately below the mesh, and at a depth of 5 cm from the surface of the phantom. The films were scanned using a scanning densitometer. In the region directly above the titanium mesh, there was an increase in dose of 7.1% for 6-MV photons and 4.9% for 18-MV photons. Directly below the titanium mesh, there was an average decrease in dose of 1.5% for 6-MV photons and an increase of 1.0% for 18-MV photons. At 5-cm depth, for 6- and 18-MV photons, there was a decrease in dose of 2.2% and 0.6%, respectively. We concluded that for cranial irradiation with high-energy photons, the dosimetric impact of a 0.4-mm titanium mesh is small and does not require modification in treatment parameters.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17134670     DOI: 10.1016/j.meddos.2006.05.001

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  4 in total

1.  Influence of backscatter radiation on cranial reconstruction implants.

Authors:  Yoshiaki Sakamoto; Naoyoshi Koike; Hideyuki Takei; Mari Ohno; Tomoru Miwa; Kazunari Yoshida; Naoyuki Shigematsu; Kazuo Kishi
Journal:  Br J Radiol       Date:  2017-01-03       Impact factor: 3.039

Review 2.  Review of the nature of some geophagic materials and their potential health effects on pregnant women: some examples from Africa.

Authors:  Selma N Kambunga; Carla Candeias; Israel Hasheela; Hassina Mouri
Journal:  Environ Geochem Health       Date:  2019-04-11       Impact factor: 4.609

3.  Monte Carlo simulation and film dosimetry for electron therapy in vicinity of a titanium mesh.

Authors:  Keyvan Jabbari; Masoumeh Rostampour; Mahnaz Roayaei
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

4.  Effects of titanium mesh implant on dosimetry during Gamma Knife radiosurgery.

Authors:  Joseph T Rakowski; Karen Chin; Sandeep Mittal
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.