Literature DB >> 17130814

Continuous glucose monitoring and external insulin pump: towards a subcutaneous closed loop.

H Hanaire1.   

Abstract

The development of an artificial pancreas for the treatment of type 1 diabetes is a highly desired endeavour for type 1 diabetic patients, physicians, scientists and engineers. The development of the first miniaturized external pumps in the 70s and the pharmacokinetic properties of short acting insulin analogues, closer to physiology, have raised hopes for the elaboration of such a device. Recent technological progress in the development of continuous glucose sensors, have improved the reliability and accuracy of these devices. This has led to the development of prototypes of closed-loop system based on the combination of a continuous monitor, a control algorithm, and an insulin pump. This review focuses on the SC-SC approach, employing subcutaneous glucose monitoring and subcutaneous insulin delivery. The feasibility of this solution has been proven at a small scale, but remains to be confirmed in the home setting. Intermediate solutions, such as semi-automatic systems, might be immediately valuable.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17130814     DOI: 10.1016/s1262-3636(06)72808-7

Source DB:  PubMed          Journal:  Diabetes Metab        ISSN: 1262-3636            Impact factor:   6.041


  11 in total

1.  Decision Support in Diabetes Care: The Challenge of Supporting Patients in Their Daily Living Using a Mobile Glucose Predictor.

Authors:  Carmen Pérez-Gandía; Gema García-Sáez; David Subías; Agustín Rodríguez-Herrero; Enrique J Gómez; Mercedes Rigla; M Elena Hernando
Journal:  J Diabetes Sci Technol       Date:  2018-03

Review 2.  Closed-Loop Insulin Delivery Systems: Past, Present, and Future Directions.

Authors:  Sophie Templer
Journal:  Front Endocrinol (Lausanne)       Date:  2022-06-06       Impact factor: 6.055

3.  Sense and nonsense in sensors.

Authors:  J Hermanides; J H DeVries
Journal:  Diabetologia       Date:  2010-01-10       Impact factor: 10.122

Review 4.  Therapeutics of diabetes mellitus: focus on insulin analogues and insulin pumps.

Authors:  Vasiliki Valla
Journal:  Exp Diabetes Res       Date:  2010-05-26

5.  Prospects and challenges for islet regeneration as a treatment for diabetes: a review of islet neogenesis associated protein.

Authors:  Alexander Fleming; Lawrence Rosenberg
Journal:  J Diabetes Sci Technol       Date:  2007-03

Review 6.  Recent progress in mechanical artificial pancreas.

Authors:  Masami Hoshino; Yoshikura Haraguchi; Iwanori Mizushima; Motohiro Sakai
Journal:  J Artif Organs       Date:  2009-09-19       Impact factor: 1.731

7.  Current application of continuous glucose monitoring in the treatment of diabetes: pros and cons.

Authors:  Jeroen Hermanides; Moshe Phillip; J Hans DeVries
Journal:  Diabetes Care       Date:  2011-05       Impact factor: 19.112

8.  Correlations of glucose levels in interstitial fluid estimated by continuous glucose monitoring systems and venous plasma.

Authors:  Byung-Joon Kim
Journal:  Korean Diabetes J       Date:  2010-12-31

9.  Encapsulation of FITC to monitor extracellular pH: a step towards the development of red blood cells as circulating blood analyte biosensors.

Authors:  Sarah C Ritter; Mark A Milanick; Kenith E Meissner
Journal:  Biomed Opt Express       Date:  2011-06-22       Impact factor: 3.732

Review 10.  Continuous Glucose Monitoring Systems: A Review.

Authors:  Sandeep Kumar Vashist
Journal:  Diagnostics (Basel)       Date:  2013-10-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.