Literature DB >> 17126460

Reconstruction of the digital flexor pulley system: a retrospective comparison of two methods of treatment.

R Arora1, D Fritz, R Zimmermann, M Lutz, F Kamelger, A S Klauser, M Gabl.   

Abstract

The rare injury of closed rupture of the A2 and A3 flexor pulleys was treated using two non-encircling techniques of pulley reconstruction. Thirteen patients were treated with an extensor retinaculum graft (Group A). At a mean follow-up time of 48 months, the average PIP flexion was 97%, the power grip strength 96%, the pinch grip strength 100% and the thickening 94% of the uninjured side. Ten patients were treated with a free palmaris longus tendon grafts (Group B). At a mean follow-up time of 57 months, the average PIP flexion was 94%, the power grip strength 98%, the pinch grip strength 100% and the thickening 95% of the uninjured side. In both groups, finger extension was unrestricted. The Buck Gramcko score included 10 excellent, two good and one fair result in Group A and seven excellent, two good and one fair result in Group B. Both techniques proved beneficial. All climbers returned to their previous standard and all non-climbers regained full finger dexterity in their previous job.

Entities:  

Mesh:

Year:  2006        PMID: 17126460     DOI: 10.1016/j.jhsb.2006.09.019

Source DB:  PubMed          Journal:  J Hand Surg Eur Vol        ISSN: 0266-7681


  11 in total

1.  Tendon injuries of the hand.

Authors:  Volker Schöffl; Andreas Heid; Thomas Küpper
Journal:  World J Orthop       Date:  2012-06-18

2.  Intermittent unspecific osteitis and cortex atrophy of the proximal phalanx after surgical pulley repair.

Authors:  Christoph Lutter; Volker Schoeffl
Journal:  BMJ Case Rep       Date:  2015-12-01

3.  The flexor tendon pulley system and rock climbing.

Authors:  Timothy P Crowley
Journal:  J Hand Microsurg       Date:  2012-01-18

Review 4.  Feet injuries in rock climbers.

Authors:  Volker Schöffl; Thomas Küpper
Journal:  World J Orthop       Date:  2013-10-18

5.  Evaluation of finger A3 pulley rupture in the crimp grip position-a magnetic resonance imaging cadaver study.

Authors:  Thomas Bayer; Werner Adler; Andreas Schweizer; Isabelle Schöffl; Michael Uder; Rolf Janka
Journal:  Skeletal Radiol       Date:  2015-05-02       Impact factor: 2.199

6.  The Effect of Pulley Reconstruction on Maximum Flexion, Bowstringing, and Gliding Coefficient in the Setting of Zone II Repair of FDS and FDP: a Cadaveric Investigation.

Authors:  Spencer J Stanbury; Christopher English; Zaneb Yaseen; Jeffrey D Reed; Tony Chen; Hani Awad; John C Elfar
Journal:  Hand (N Y)       Date:  2014-03

7.  Surface Modification with Chemically Modified Synovial Fluid for Flexor Tendon Reconstruction in a Canine Model in Vivo.

Authors:  Xiaoxi Ji; Ramona L Reisdorf; Andrew R Thoreson; Lawrence R Berglund; Steven L Moran; Gregory D Jay; Kai-Nan An; Peter C Amadio; Chunfeng Zhao
Journal:  J Bone Joint Surg Am       Date:  2015-06-17       Impact factor: 5.284

Review 8.  Closed flexor pulley injuries: A literature review and current practice.

Authors:  Francesco Bosco; Fortunato Giustra; Alessandro Lusso; Carlotta Faccenda; Stefano Artiaco; Alessandro Massè
Journal:  J Orthop       Date:  2022-09-09

9.  Resurfacing with chemically modified hyaluronic acid and lubricin for flexor tendon reconstruction.

Authors:  Chunfeng Zhao; Takahiro Hashimoto; Ramona L Kirk; Andrew R Thoreson; Gregory D Jay; Steven L Moran; Kai-Nan An; Peter C Amadio
Journal:  J Orthop Res       Date:  2013-01-17       Impact factor: 3.494

10.  The epidemiology of reoperation after flexor pulley reconstruction.

Authors:  Christopher J Dy; Stephen Lyman; Joseph J Schreiber; Huong T Do; Aaron Daluiski
Journal:  J Hand Surg Am       Date:  2013-07-08       Impact factor: 2.230

View more