Literature DB >> 17126412

Reproducibility of sonotubometry as Eustachian tube ventilatory function test in healthy children.

Stijn J C van der Avoort1, Niels van Heerbeek, Ad F M Snik, Gerhard A Zielhuis, Cor W R J Cremers.   

Abstract

OBJECTIVES: To devise a simple and reliable diagnostic procedure to test Eustachian tube function routinely in an ENT outpatient setting. One method to measure ET ventilatory function is sonotubometry. The reproducibility of a recently updated sonotubometry set-up was tested in healthy children.
METHODS: The test population comprised 61 school children aged from 6 to 8 years. Only otologically healthy children were included. Health state was established by means of a 12-item questionnaire. To test reproducibility, sonotubometric testing took place in two sessions of 10 acts of swallowing each. Spearman's coefficient was used to test the correlation between the two sets of measurements. All testing took place at a primary school in a nearby village.
RESULTS: Opening of the ET was recorded in at least one of the two measurement sessions in 82% of the children. The first and second sessions were highly correlated, with a Spearman's coefficient of 0.89.
CONCLUSIONS: In otologically healthy children, opening of the ET was recorded frequently using the updated sonotubometry set-up. Measurement results had high reproducibility. Therefore, the test forms a useful method to assess ET ventilatory function in otologically healthy children. The performance of this updated version needs to be established in children with otological diseases.

Entities:  

Mesh:

Year:  2006        PMID: 17126412     DOI: 10.1016/j.ijporl.2006.10.015

Source DB:  PubMed          Journal:  Int J Pediatr Otorhinolaryngol        ISSN: 0165-5876            Impact factor:   1.675


  5 in total

1.  Correlations between videoendoscopy and sonotubometry of eustachian tube opening during a swallow.

Authors:  Cuneyt M Alper; Miriam S Teixeira; J Douglas Swarts
Journal:  Laryngoscope       Date:  2016-03-24       Impact factor: 3.325

2.  A method to assess the accuracy of sonotubometry for detecting Eustachian tube openings.

Authors:  J Douglas Swarts; Miriam S Teixeira; Juliane Banks; Jenna El-Wagaa; William J Doyle
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-04-08       Impact factor: 2.503

3.  Evaluation of Eustachian tube function with perfect sequences: technical realization and first clinical results.

Authors:  Ercole F N Di Martino; Viorel Nath; Aulis Telle; Christiane Antweiler; Leif E Walther; P Vary
Journal:  Eur Arch Otorhinolaryngol       Date:  2009-09-01       Impact factor: 2.503

4.  Eustachian Tube Opening Measurement by Sonotubometry Using Perfect Sequences for Healthy Adults.

Authors:  Vilma Beleskiene; Eugenijus Lesinskas; Vaida Januskiene; Kristina Daunoraviciene; Darius Rauba; Justinas Ivaska
Journal:  Clin Exp Otorhinolaryngol       Date:  2016-04-19       Impact factor: 3.372

5.  Interpretation of sonotubometric data based on phase-shift detection.

Authors:  Yaw Amoako-Tuffour; Philip Garland; Manohar Bance
Journal:  J Otolaryngol Head Neck Surg       Date:  2016-06-10
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.