Literature DB >> 17122016

Controlled clinical comparison of VersaTREK and BacT/ALERT blood culture systems.

Stanley Mirrett1, Kimberly E Hanson, L Barth Reller.   

Abstract

To assess the relative yields in automated microbial detection systems of bacteria and yeasts isolated from the blood of adult patients with suspected sepsis, we compared the new VersaTREK system (VTI) (TREK Diagnostic Systems, Cleveland, OH) to the BacT/ALERT 3D system (3D) (bioMérieux, Inc., Durham, NC). Identical protocols were followed for the two systems. Paired aerobic (REDOX 1) and anaerobic (REDOX 2) VTI media were compared with standard aerobic (SA) and anaerobic (SN) 3D media; each of the four culture bottles was filled with 6 to 9 ml of blood. All bottles flagged positive by the instruments were subcultured to determine both true-positive (growth) and false-positive (no growth) cultures. Additionally, to assess false-negative bottles, terminal subcultures were done on all negative companion bottles to true-positive bottles. All isolates were identified by standard methods. All 4 bottles were adequately filled and yielded 413 clinically significant isolates in 5,389 (79%) of the 6,786 4-bottle sets obtained. Although no overall difference in yield or in time to detection was detected between the two systems, significantly more streptococci and enterococci as a group were detected by VTI. Moreover, significantly more microorganisms were detected by VTI for patients receiving antimicrobial therapy. The two systems were comparable (P, not significant) at detecting the 179 unimicrobial episodes of bacteremia seen. False-positive rates for aerobic and anaerobic bottles, respectively, were 1.6% and 0.9% for VTI and 0.7% and 0.8% for 3D. We conclude that the VTI and 3D systems are comparable for detection of bloodstream infections with bacteria or yeasts.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17122016      PMCID: PMC1829065          DOI: 10.1128/JCM.01697-06

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  5 in total

1.  Controlled comparative evaluation of BacT/Alert FAN and ESP 80A aerobic media as means for detecting bacteremia and fungemia.

Authors:  G V Doern; A Barton; S Rao
Journal:  J Clin Microbiol       Date:  1998-09       Impact factor: 5.948

Review 2.  Current blood culture methods and systems: clinical concepts, technology, and interpretation of results.

Authors:  M P Weinstein
Journal:  Clin Infect Dis       Date:  1996-07       Impact factor: 9.079

3.  The clinical significance of positive blood cultures in the 1990s: a prospective comprehensive evaluation of the microbiology, epidemiology, and outcome of bacteremia and fungemia in adults.

Authors:  M P Weinstein; M L Towns; S M Quartey; S Mirrett; L G Reimer; G Parmigiani; L B Reller
Journal:  Clin Infect Dis       Date:  1997-04       Impact factor: 9.079

4.  Comparison of Difco ESP and Organon Teknika BacT/Alert continuous-monitoring blood culture systems.

Authors:  P Zwadyk; C L Pierson; C Young
Journal:  J Clin Microbiol       Date:  1994-05       Impact factor: 5.948

5.  Controlled clinical evaluation of Isolator and ESP aerobic blood culture systems for detection of bloodstream infections.

Authors:  B A Kirkley; K A Easley; J A Washington
Journal:  J Clin Microbiol       Date:  1994-06       Impact factor: 5.948

  5 in total
  11 in total

1.  Performance evaluation of the VersaTREK blood culture system for quality control testing of platelet units.

Authors:  Suparna Nanua; Carol Weber; Liz Isgriggs; W Michael Dunne
Journal:  J Clin Microbiol       Date:  2009-01-14       Impact factor: 5.948

2.  Comparison of BD Bactec Plus Aerobic/F medium to VersaTREK Redox 1 blood culture medium for detection of Candida spp. in seeded blood culture specimens containing therapeutic levels of antifungal agents.

Authors:  Stefan Riedel; Stephen W Eisinger; Lisa Dam; Paul D Stamper; Karen C Carroll
Journal:  J Clin Microbiol       Date:  2011-01-26       Impact factor: 5.948

3.  Evaluation of the BD BACTEC FX blood volume monitoring system as a continuous quality improvement measure.

Authors:  L Coorevits; A-M Van den Abeele
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2015-04-17       Impact factor: 3.267

4.  Comparative analysis of two broad-range PCR assays for pathogen detection in positive-blood-culture bottles: PCR-high-resolution melting analysis versus PCR-mass spectrometry.

Authors:  Kevin Jeng; Charlotte A Gaydos; Lawrence B Blyn; Samuel Yang; Helen Won; Heather Matthews; Donna Toleno; Yu-Hsiang Hsieh; Karen C Carroll; Justin Hardick; Billy Masek; Alexander Kecojevic; Rangarajan Sampath; Stephen Peterson; Richard E Rothman
Journal:  J Clin Microbiol       Date:  2012-08-01       Impact factor: 5.948

Review 5.  Molecular microbiological methods in the diagnosis of neonatal sepsis.

Authors:  Mohan Venkatesh; Angela Flores; Ruth Ann Luna; James Versalovic
Journal:  Expert Rev Anti Infect Ther       Date:  2010-09       Impact factor: 5.091

6.  Rapid real-time nucleic Acid sequence-based amplification-molecular beacon platform to detect fungal and bacterial bloodstream infections.

Authors:  Yanan Zhao; Steven Park; Barry N Kreiswirth; Christine C Ginocchio; Raphaël Veyret; Ali Laayoun; Alain Troesch; David S Perlin
Journal:  J Clin Microbiol       Date:  2009-04-29       Impact factor: 5.948

7.  Real-World Evaluation of the Impact of Implementation of the Virtuo Blood Culture System in a Tertiary Care Hospital.

Authors:  Miguel A Chavez; Satish Munigala; Carey-Ann D Burnham; Melanie L Yarbrough; David K Warren
Journal:  J Clin Microbiol       Date:  2021-07-14       Impact factor: 5.948

8.  Comparison of the VersaTREK blood culture system against the Bactec9240 system in patients with suspected bloodstream infections.

Authors:  Andries W Dreyer; Nazir A Ismail; Deliwe Nkosi; Kathy Lindeque; Marliza Matthews; Danie G van Zyl; Anwar A Hoosen
Journal:  Ann Clin Microbiol Antimicrob       Date:  2011-02-05       Impact factor: 3.944

9.  Comparison of methods for identifying causative bacterial microorganisms in presumed acute endophthalmitis: conventional culture, blood culture, and PCR.

Authors:  Pear Pongsachareonnont; Worawalun Honglertnapakul; Tanittha Chatsuwan
Journal:  BMC Infect Dis       Date:  2017-02-21       Impact factor: 3.090

10.  Comparison of the Performance of Three Blood Culture Systems in a Chinese Tertiary-Care Hospital.

Authors:  Guanlin Li; Jingjing Sun; Shoucheng Pan; Wenti Li; Shijie Zhang; Yongfeng Wang; Xiaoxu Sun; Hui Xu; Liang Ming
Journal:  Front Cell Infect Microbiol       Date:  2019-08-07       Impact factor: 5.293

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.