Literature DB >> 17120012

Online optical coherence pachymetry to evaluate intraoperative ablation parameters in LASIK.

Christopher Wirbelauer1, Henning Aurich, Duy Thoai Pham.   

Abstract

PURPOSE: The ablation of corneal tissue with the excimer laser can be variable and can lead to miscorrections. The purpose of this study was to evaluate intraoperative ablation parameters during laser-assisted in-situ keratomileusis (LASIK) with online optical coherence pachymetry (OCP).
METHODS: In a prospective, nonrandomized, comparative clinical study, the ablation parameters were continuously assessed intraoperatively with online OCP (Heidelberg Engineering, Lübeck, Germany) in 45 myopic and 10 hyperopic LASIK treatments. The central intraoperative ablation values were compared with the calculated values of the excimer laser (ESIRIS, Schwind, Germany) and the postoperative refraction. The ablation process and the ablation rate in mum per layer, time, and dioptric correction were evaluated in myopic corrections.
RESULTS: In myopic LASIK treatments, a linear ablation process was measured with a mean correlation coefficient of -0.968 +/- 0.04. The intraoperative ablation rate was, on average, 0.59 +/- 0.17 microm per layer, 1.45 +/- 0.48 microm per second, and 24.63 +/- 7.81 microm per corrected diopter. These values were 28.7% to 29.6% higher (P < 0.001) than the calculated values. There was a significant correlation (P < 0.001) for the ablation rate per layer (r = 0.823), per second (r = 0.869), and corrected diopter (r = 0.892), but no correlation (r = 0.21, P = 0.239) between the measured linear ablation process and the postoperative refraction. During hyperopic LASIK treatments, without ablation of the corneal center, there was a significant decrease (P = 0.005) of the stromal thickness by 18.34 +/- 14.13 microm, which corresponded to a mean corneal dehydration rate of 0.27 microm per second.
CONCLUSIONS: Online OCP allowed a clinical evaluation of intraoperative ablation parameters in LASIK. Further studies are needed to assess a possible active control of the excimer laser ablation from these continuous values, which could possibly improve current ablation nomograms.

Entities:  

Mesh:

Year:  2006        PMID: 17120012     DOI: 10.1007/s00417-006-0447-7

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.535


  31 in total

1.  Corneal optical coherence tomography before and immediately after excimer laser photorefractive keratectomy.

Authors:  C Wirbelauer; C Scholz; H Hoerauf; R Engelhardt; R Birngruber; H Laqua
Journal:  Am J Ophthalmol       Date:  2000-12       Impact factor: 5.258

2.  The predictability of corneal flap thickness and tissue laser ablation in laser in situ keratomileusis.

Authors:  V D Durairaj; J Balentine; G Kouyoumdjian; J A Tooze; D Young; L Spivack; M J Taravella
Journal:  Ophthalmology       Date:  2000-12       Impact factor: 12.079

3.  Corneal tissue ablation depth and the Munnerlyn formula.

Authors:  Austin W Chang; Alexander C Tsang; Janice E Contreras; Paul D Huynh; Christopher J Calvano; Tracy C Crnic-Rein; Edmond H Thall
Journal:  J Cataract Refract Surg       Date:  2003-06       Impact factor: 3.351

4.  Laser in situ keratomileusis induced corneal perforation and recurrent corneal epithelial ingrowth.

Authors:  Quan Liu; Xiang Ming Gong; Jia Qi Chen; Bin Yang; Jian Ge; Chi Ho To
Journal:  J Cataract Refract Surg       Date:  2005-04       Impact factor: 3.351

5.  Measurement of small-signal absorption coefficient and absorption cross section of collagen for 193-nm excimer laser light and the role of collagen in tissue ablation.

Authors:  Brian T Fisher; David W Hahn
Journal:  Appl Opt       Date:  2004-10-10       Impact factor: 1.980

6.  Excimer laser ablation rate and corneal hydration.

Authors:  P J Dougherty; K L Wellish; R K Maloney
Journal:  Am J Ophthalmol       Date:  1994-08-15       Impact factor: 5.258

7.  Corneal hydration affects ablation during laser in situ keratomileusis surgery.

Authors:  W S Kim; J M Jo
Journal:  Cornea       Date:  2001-05       Impact factor: 2.651

8.  Determination of excimer laser ablation rate of the human cornea using in vivo Scheimpflug videography.

Authors:  H J Huebscher; U Genth; T Seiler
Journal:  Invest Ophthalmol Vis Sci       Date:  1996-01       Impact factor: 4.799

9.  Assessment of transient changes in corneal hydration using confocal Raman spectroscopy.

Authors:  Brian T Fisher; Kathryn A Masiello; Michael H Goldstein; David W Hahn
Journal:  Cornea       Date:  2003-05       Impact factor: 2.651

10.  Ultrasound evaluation of flap thickness, ablation depth, and corneal edema after laser in situ keratomileusis.

Authors:  Zoltán Z Nagy; Miklós Resch; Ildikó Süveges
Journal:  J Refract Surg       Date:  2004 May-Jun       Impact factor: 3.573

View more
  3 in total

1.  Corneal stromal dehydration and optimal stromal exposure time during corneal refractive surgery measured using a three-dimensional optical profiler.

Authors:  Yanan Wu; Yan Wang; Zimiao Zhang; Xingchen Yu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-07-25       Impact factor: 3.535

2.  Interfaces detection after corneal refractive surgery by low coherence optical interferometry.

Authors:  I Verrier; C Veillas; T Lépine; F Nguyen; G Thuret; P Gain
Journal:  Biomed Opt Express       Date:  2010-11-19       Impact factor: 3.732

3.  The art of nomograms.

Authors:  Samuel Arba Mosquera; Diego de Ortueta; Shwetabh Verma
Journal:  Eye Vis (Lond)       Date:  2018-01-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.