Evaluation and comparison of 50 Hz current threshold of electrocutaneous sensations using different methods.

G Lindenblatt1, J Silny.   

Abstract

Leakage currents, tiny currents flowing from an everyday-life appliance through the body to the ground, can cause a non-adequate perception (called electrocutaneous sensation, ECS) or even pain and should be avoided. Safety standards for low-frequency range are based on experimental results of current thresholds of electrocutaneous sensations, which however show a wide range between about 50 microA (rms) and 1000 microA (rms). In order to be able to explain these differences, the perception threshold was measured repeatedly in experiments with test persons under identical experimental setup, but by means of different methods (measuring strategies), namely: direct adjustment, classical threshold as amperage of 50% perception probability, and confidence rating procedure of signal detection theory. The current is injected using a 1 cm2 electrode at the highly touch sensitive part of the index fingertip. These investigations show for the first time that the threshold of electrocutaneous sensations is influenced both by adaptation to the non-adequate stimulus and individual, emotional factors. Therefore, classical methods, on which the majority of the safety investigations are based, cannot be used to determine a leakage current threshold.The confidence rating procedure of the modern signal detection theory yields a value of 179.5 microA (rms) at 50 Hz power supply net frequency as the lower end of the 95% confidence range considering the variance in the investigated group. This value is expected to be free of adaptation influences, and is distinctly lower than the European limits and supports the stricter regulations of Canada and USA.

Entities:  

Mesh:

Year:  2006        PMID: 17111461      PMCID: PMC1661674          DOI: 10.1631/jzus.2006.B0933

Source DB:  PubMed          Journal:  J Zhejiang Univ Sci B        ISSN: 1673-1581            Impact factor:   3.066


  13 in total

1.  The thickness of the skin.

Authors:  W F SOUTHWOOD
Journal:  Plast Reconstr Surg (1946)       Date:  1955-05

2.  Electrotactile and vibrotactile displays for sensory substitution systems.

Authors:  K A Kaczmarek; J G Webster; P Bach-y-Rita; W J Tompkins
Journal:  IEEE Trans Biomed Eng       Date:  1991-01       Impact factor: 4.538

3.  Perception of chassis leakage current.

Authors:  M Levin
Journal:  Biomed Instrum Technol       Date:  1991 Mar-Apr

4.  Tactile sensibility in the human hand: relative and absolute densities of four types of mechanoreceptive units in glabrous skin.

Authors:  R S Johansson; A B Vallbo
Journal:  J Physiol       Date:  1979-01       Impact factor: 5.182

5.  New values for epidermal thickness and their importance.

Authors:  J T Whitton
Journal:  Health Phys       Date:  1973-01       Impact factor: 1.316

6.  The thickness of the epidermis.

Authors:  J T Whitton; J D Everall
Journal:  Br J Dermatol       Date:  1973-11       Impact factor: 9.302

7.  Reliability and interjudgment predictability of subjective judgments of electrocutaneous stimulation.

Authors:  B Tursky; D O'Connell
Journal:  Psychophysiology       Date:  1972-05       Impact factor: 4.016

8.  Properties of cutaneous mechanoreceptors in the human hand related to touch sensation.

Authors:  A B Vallbo; R S Johansson
Journal:  Hum Neurobiol       Date:  1984

9.  [Risk from electric current greater than assumed].

Authors:  N Leitgeb; J Schröttner
Journal:  Biomed Tech (Berl)       Date:  2001-11       Impact factor: 1.411

10.  Threshold of sensation for 60-Hz leakage current: results of a survey.

Authors:  K S Tan; D L Johnson
Journal:  Biomed Instrum Technol       Date:  1990 May-Jun
View more
  1 in total

1.  Phase Angle Measurement in Healthy Human Subjects through Bio-Impedance Analysis.

Authors:  Satish Kumar; Aswini Dutt; Sandhya Hemraj; Shankar Bhat; Bhat Manipadybhima
Journal:  Iran J Basic Med Sci       Date:  2012-11       Impact factor: 2.699

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.