Literature DB >> 17109971

Heterophile antibody interference in a solid phase sandwich immunoassay for detection of equine growth hormone in plasma.

V Borromeo1, A Berrini, D Gaggioli, C Secchi.   

Abstract

Heterophile antibodies (HAs) present in serum recognize animal immunoglobulins and are one of the most unpredictable causes of false results in immunoassays. However, no study has yet reported their interference on the diagnostic reliability of immunochemical analyses on horse plasma. Recently, we developed a sandwich ELISA for detection of equine growth hormone (eGH) in plasma. In a pilot study to measure basal eGH levels (blood samples were drawn from 13 horses every 10 min for 1h), we noted one horse with abnormally high eGH (>100 ng/mL). We demonstrate here that this plasma eGH level was falsely elevated due to interference from HAs. The interfering antibodies were polyspecific immunoglobulins, with fairly broad species-specificity, which affected the eGH immunoassay by bridging the mouse IgG capture antibody and the rabbit IgG conjugate. This produced artificial sandwiches which led to overestimation of the eGH plasma concentration. Spiking horse plasma with pure mouse and rabbit immunoglobulins or whole plasma of several species significantly reduced but did not totally eliminate the HAs interference. Immunoglobulins and whole plasma differed in their ability to block the interference, suggesting that HAs may recognize other proteins beside immunoglobulins in animal sera. To investigate whether HAs have any implications in equine clinical practice, we decided to seek information on the incidence of HAs interference in normal animals. We collected single plasma samples from another 114 horses and we found that 5 of these had plasma HAs. Therefore, in total 6 out of the 127 horses examined (4.7%) had plasma HAs generating falsely elevated eGH measures. In conclusion, this study provides the first evidence of HAs in horse plasma interfering with an immunoassay and indicates that veterinary surgeons and diagnostic laboratory staff should be aware of this potential for interference in tests on horse plasma using monoclonal or polyclonal antibody reagents.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17109971     DOI: 10.1016/j.vetimm.2006.10.010

Source DB:  PubMed          Journal:  Vet Immunol Immunopathol        ISSN: 0165-2427            Impact factor:   2.046


  3 in total

1.  Growth hormone secretion in relation to plasma lactate and glucose concentrations during a maximal treadmill exercise test in horses.

Authors:  V Borromeo; F Ferrucci; E Zucca; A Berrini; C Secchi
Journal:  Vet Res Commun       Date:  2008-09       Impact factor: 2.459

2.  Development of a Multiplexed Assay for Oral Cancer Candidate Biomarkers Using Peptide Immunoaffinity Enrichment and Targeted Mass Spectrometry.

Authors:  Yung-Chin Hsiao; Lang-Ming Chi; Kun-Yi Chien; Wei-Fan Chiang; Szu-Fan Chen; Yao-Ning Chuang; Shih-Yu Lin; Chia-Chun Wu; Ya-Ting Chang; Lichieh Julie Chu; Yi-Ting Chen; Shu-Li Chia; Chih-Yen Chien; Kai-Ping Chang; Yu-Sun Chang; Jau-Song Yu
Journal:  Mol Cell Proteomics       Date:  2017-08-18       Impact factor: 5.911

3.  Prevalence of heterophilic antibodies in serum samples from horses in an equine hospital, and elimination of interference using chicken IgY.

Authors:  Bo Dong; Daniel Bergman; Bodil Ström Holst
Journal:  Acta Vet Scand       Date:  2021-03-12       Impact factor: 1.695

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.