Literature DB >> 17109952

Numerical modeling of the fracture process in a three-unit all-ceramic fixed partial denture.

Wen Kou1, Shaoquan Kou, Hongyuan Liu, Göran Sjögren.   

Abstract

OBJECTIVES: The main objectives were to examine the fracture mechanism and process of a ceramic fixed partial denture (FPD) framework under simulated mechanical loading using a recently developed numerical modeling code, the R-T(2D) code, and also to evaluate the suitability of R-T(2D) code as a tool for this purpose.
METHODS: Using the recently developed R-T(2D) code the fracture mechanism and process of a 3U yttria-tetragonal zirconia polycrystal ceramic (Y-TZP) FPD framework was simulated under static loading. In addition, the fracture pattern obtained using the numerical simulation was compared with the fracture pattern obtained in a previous laboratory test.
RESULTS: The result revealed that the framework fracture pattern obtained using the numerical simulation agreed with that observed in a previous laboratory test. Quasi-photoelastic stress fringe pattern and acoustic emission showed that the fracture mechanism was tensile failure and that the crack started at the lower boundary of the framework. The fracture process could be followed both in step-by-step and step-in-step. SIGNIFICANCE: Based on the findings in the current study, the R-T(2D) code seems suitable for use as a complement to other tests and clinical observations in studying stress distribution, fracture mechanism and fracture processes in ceramic FPD frameworks.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17109952     DOI: 10.1016/j.dental.2006.06.039

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  6 in total

Review 1.  Performance of dental ceramics: challenges for improvements.

Authors:  E D Rekow; N R F A Silva; P G Coelho; Y Zhang; P Guess; V P Thompson
Journal:  J Dent Res       Date:  2011-01-11       Impact factor: 6.116

2.  Prosthodontic rehabilitation of a patient with aggressive periodontitis.

Authors:  David Livingstone; Varsha Murthy; Vineela Katam Reddy; Ajay Pillai
Journal:  BMJ Case Rep       Date:  2015-03-05

3.  Reliability and fatigue failure modes of implant-supported aluminum-oxide fixed dental prostheses.

Authors:  Christian F J Stappert; Marta Baldassarri; Yu Zhang; Felix Hänssler; Elizabeth D Rekow
Journal:  Clin Oral Implants Res       Date:  2011-09-05       Impact factor: 5.977

4.  Fracture resistance and failure mode of posterior fixed dental prostheses fabricated with two zirconia CAD/CAM systems.

Authors:  Carlos López-Suárez; Esther Gonzalo; Jesús Peláez; Verónica Rodríguez; María-Jesús Suárez
Journal:  J Clin Exp Dent       Date:  2015-04-01

5.  Aesthetic rehabilitation with multiple loop connectors.

Authors:  Ashish Kalra; Mahesh E Gowda; Kamal Verma
Journal:  Contemp Clin Dent       Date:  2013-01

6.  Preparation, Microstructure, Mechanical Properties and Biocompatibility of Ta-Coated 3Y-TZP Ceramic Deposited by a Plasma Surface Alloying Technique.

Authors:  Ke Zheng; Liangliang Li; Yaqian Dong; Jie Gao; Hongjun Hei; Yong Ma; Bin Zhou; Zhiyong He; Yongsheng Wang; Shengwang Yu; Bin Tang; Yucheng Wu
Journal:  Materials (Basel)       Date:  2020-03-11       Impact factor: 3.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.