Chi Wai Yip1, Chung Chau Hon, Fanya Zeng, Ken Y C Chow, Kwok Hung Chan, Joseph S M Peiris, Frederick C C Leung.
Abstract
We reported the analytical interference of anti-Escherichia coli protein (EP) antibodies in human sera and residual EP in a recombinant nucleocapsid protein-based enzyme-linked immunosorbent assay as a possible source of false positives in severe acute respiratory syndrome serodiagnosis. The rate of false positives was significantly reduced by adding mouse anti-EP antiserum in the blocking step.Entities:
Mesh:
Substances:
Year: 2006 PMID: 17108287 PMCID: PMC1797702 DOI: 10.1128/CVI.00136-06