Literature DB >> 17107650

Calibration in isothermal titration calorimetry: heat and cell volume from heat of dilution of NaCl(aq).

Joel Tellinghuisen1.   

Abstract

An isothermal titration calorimeter of the perfusion type (MicroCal model VP-ITC) is calibrated using the heat of dilution of NaCl in water. The relative apparent molar enthalpy function (L(phi)) for NaCl(aq) varies strongly and nonlinearly with concentration in the low-concentration region (<0.2M) that is sampled easily and extensively in a single program of injections of NaCl solution into water. This nonlinearity makes it possible to calibrate with respect to two quantities: the measured heat and the active cell volume. The heat factor is determined with typical standard error 0.003; its value in the current case is 0.987. The cell volume factor is 0.93 but is quite sensitive to possible systematic errors in the temperature and in the literature values for L(phi). Both correction factors are closely tied to the delivered volume from the injection syringe, which required a correction factor of 0.973, attributed to an instrumental gear ratio error. Temperature calibration of the instrument showed a small offset of 0.12K at the temperature 25 degrees C of the experiments, but the error increased to more than 1K at 46 degrees C. The experiments were not able to distinguish clearly between mixing algorithms that assume instantaneous mixing on injection and those that assume instantaneous injection followed by mixing; however, examination of these algorithms has revealed an error in a program widely used to analyze isothermal titration calorimetry data.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17107650     DOI: 10.1016/j.ab.2006.10.015

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  15 in total

Review 1.  Applications of isothermal titration calorimetry in RNA biochemistry and biophysics.

Authors:  Andrew L Feig
Journal:  Biopolymers       Date:  2007 Dec 5-15       Impact factor: 2.505

2.  An explicit formulation approach for the analysis of calcium binding to EF-hand proteins using isothermal titration calorimetry.

Authors:  Camille Keeler; Gregory Poon; Ivana Y Kuo; Barbara E Ehrlich; Michael E Hodsdon
Journal:  Biophys J       Date:  2013-12-17       Impact factor: 4.033

3.  Isothermal titration calorimetry (ITC): a standard operating procedure (SOP).

Authors:  Margarida Bastos; Adrian Velazquez-Campoy
Journal:  Eur Biophys J       Date:  2021-03-04       Impact factor: 1.733

4.  Understanding detergent effects on lipid membranes: a model study of lysolipids.

Authors:  Jonas R Henriksen; Thomas L Andresen; Lise N Feldborg; Lars Duelund; John H Ipsen
Journal:  Biophys J       Date:  2010-05-19       Impact factor: 4.033

5.  Cross-platform comparison of nucleic acid hybridization: toward quantitative reference standards.

Authors:  Ken Halvorsen; Paul F Agris
Journal:  Anal Biochem       Date:  2014-08-12       Impact factor: 3.365

6.  Obtaining precise and accurate results by ITC.

Authors:  Lee D Hansen; Colette Quinn
Journal:  Eur Biophys J       Date:  2019-09-25       Impact factor: 1.733

7.  Isothermal titration calorimetry in the single-injection mode with imperfect mixing.

Authors:  Philippe Dumas
Journal:  Eur Biophys J       Date:  2022-01-08       Impact factor: 1.733

Review 8.  A medicinal chemist's guide to molecular interactions.

Authors:  Caterina Bissantz; Bernd Kuhn; Martin Stahl
Journal:  J Med Chem       Date:  2010-07-22       Impact factor: 7.446

9.  A microfabricated nanocalorimeter: design, characterization, and chemical calibration.

Authors:  Junkai Xu; Ron Reiserer; Joel Tellinghuisen; John P Wikswo; Franz J Baudenbacher
Journal:  Anal Chem       Date:  2008-03-20       Impact factor: 6.986

10.  Titration calorimetry standards and the precision of isothermal titration calorimetry data.

Authors:  Lina Baranauskienė; Vilma Petrikaitė; Jurgita Matulienė; Daumantas Matulis
Journal:  Int J Mol Sci       Date:  2009-06-18       Impact factor: 6.208

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.