Literature DB >> 17106469

On the fundamental imaging-depth limit in two-photon microscopy.

Patrick Theer1, Winfried Denk.   

Abstract

We have analyzed how the maximal imaging depth of two-photon microscopy in scattering samples depends on properties of the sample and the imaging system. We find that the imaging depth increases with increasing numerical aperture and staining inhomogeneity and with decreasing excitation-pulse duration and scattering anisotropy factor, but is ultimately limited by near-surface fluorescence with slight improvements possible using special detection strategies.

Mesh:

Year:  2006        PMID: 17106469     DOI: 10.1364/josaa.23.003139

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  126 in total

Review 1.  Two-photon microscopy as a tool to study blood flow and neurovascular coupling in the rodent brain.

Authors:  Andy Y Shih; Jonathan D Driscoll; Patrick J Drew; Nozomi Nishimura; Chris B Schaffer; David Kleinfeld
Journal:  J Cereb Blood Flow Metab       Date:  2012-02-01       Impact factor: 6.200

2.  A CANDLE for a deeper in vivo insight.

Authors:  Pierrick Coupé; Martin Munz; Jose V Manjón; Edward S Ruthazer; D Louis Collins
Journal:  Med Image Anal       Date:  2012-01-18       Impact factor: 8.545

3.  Shack-Hartmann wavefront-sensor-based adaptive optics system for multiphoton microscopy.

Authors:  Jae Won Cha; Jerome Ballesta; Peter T C So
Journal:  J Biomed Opt       Date:  2010 Jul-Aug       Impact factor: 3.170

4.  Axial range of conjugate adaptive optics in two-photon microscopy.

Authors:  Hari P Paudel; John Taranto; Jerome Mertz; Thomas Bifano
Journal:  Opt Express       Date:  2015-08-10       Impact factor: 3.894

5.  Comparison of objective lenses for multiphoton microscopy in turbid samples.

Authors:  Avtar Singh; Jesse D McMullen; Eli A Doris; Warren R Zipfel
Journal:  Biomed Opt Express       Date:  2015-07-30       Impact factor: 3.732

6.  Cortical spreading depression impairs oxygen delivery and metabolism in mice.

Authors:  Izumi Yuzawa; Sava Sakadžić; Vivek J Srinivasan; Hwa Kyoung Shin; Katharina Eikermann-Haerter; David A Boas; Cenk Ayata
Journal:  J Cereb Blood Flow Metab       Date:  2011-10-19       Impact factor: 6.200

7.  Enhancement of imaging depth in turbid media using a wide area detector.

Authors:  Viera Crosignani; Alexander S Dvornikov; Enrico Gratton
Journal:  J Biophotonics       Date:  2011-03-18       Impact factor: 3.207

8.  Enhanced background rejection in thick tissue with differential-aberration two-photon microscopy.

Authors:  A Leray; K Lillis; J Mertz
Journal:  Biophys J       Date:  2007-10-19       Impact factor: 4.033

9.  Improving Signal Levels in Intravital Multiphoton Microscopy using an Objective Correction Collar.

Authors:  Pamela A Muriello; Kenneth W Dunn
Journal:  Opt Commun       Date:  2008-04-01       Impact factor: 2.310

10.  Longitudinal in vivo two-photon fluorescence imaging.

Authors:  Sarah E Crowe; Graham C R Ellis-Davies
Journal:  J Comp Neurol       Date:  2014-06-01       Impact factor: 3.215