Literature DB >> 17106147

Appropriate ICD therapy in patients with idiopathic dilated cardiomyopathy: long term follow-up.

Remzi Karaoguz1, Sevgül Maydanozcu, Timuçin Altun, Muharrem Güldal, Omer Akyürek, Cetin Erol.   

Abstract

The implantable cardioverter defibrillator (ICD) has proved effective in preventing sudden death and decreasing mortality in randomised secondary prevention trials. Some nonrandomized studies have reported different incidences and predictors of appropriate ICD therapy in patients with idiopathic dilated cardiomyopathy (DCM). The antiarrhythmic and other medical therapies were different between the published studies and it was reported that not using beta-blockers was a predictor of appropriate ICD therapy. In the present study, we report on our long-term experience with ICD therapy in patients with DCM, the majority of whom were treated with beta-blockers and amiodarone. The study population consisted of 25 patients with DCM who underwent initial transvenous ICD implantation between December 1995 and May 2005. Indications for ICD implantation were monomorphic sustained ventricular tachycardia (VT) in 16 patients (64%), cardiac arrest in 8 patients (32%), and syncope plus inducible VT in one patient. Twenty-four patients underwent an electrophysiologic study (EPS). In 18 patients, the ICDs were programmed to only shocks and in 7 patients an additional antitachycardia pacing program was performed. One patient was lost to follow-up and 24 patients were followed-up primarily in our ICD pacemaker outpatient clinic. Appropriate ICD therapy was defined as antitachycardia pacing therapy or shock for tachyarrhythmia determined by evaluation of the clinical information and by device diagnostics to be either ventricular fibrillation or ventricular tachycardia. The mean follow-up was 39.29 +/- 30.59 months after ICD implantation. At follow-up, 17 patients were using a beta-blocker and 16 patients amiodarone. Appropriate ICD therapy was observed in 14 patients (58%). The detected arrhythmias were VT in 12 patients, ventricular fibrillation (VF) in one, and VT and VF in one patient. The time to first ICD therapy was 15.93 +/- 18.45 (range, 1-74) months. Using the Kaplan-Meier method, the percent survival free of appropriate ICD therapy was 82%, 72%, 66%, and 55% at 1, 2, 3, and 4 years follow-up, respectively. The clinical, echocardiographic, and electrophysiologic characteristics did not differ between those who did and did not receive appropriate ICD therapy. However, the mean QRS duration was significantly longer in patients who received appropriate ICD therapies. Cox regression analysis did not reveal any factors that predicted appropriate ICD therapy. Five patients (21%) died during follow-up. Four deaths were classified as cardiac and one as noncardiac. The cumulative survival from total death was 94%, 82%, 82%, and 69%, and the cumulative survival from cardiac death was 94%, 82%, 82%, and 76% during 1, 2, 3, and 4 years of follow-up, respectively. In summary, in this selected patient population with DCM, the majority of patients were unresponsive to beta-blocker and antiarrhythmic therapy. Most of these patients received appropriate ICD therapy during follow-up. Cox regression analysis did not identify any factors that predicted appropriate ICD therapy. Additional trials with larger patient populations are needed to detect the predictors of appropriate ICD therapy in patients with DCM.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17106147     DOI: 10.1536/ihj.47.763

Source DB:  PubMed          Journal:  Int Heart J        ISSN: 1349-2365            Impact factor:   1.862


  3 in total

1.  Prognostic impact of recurrences of ventricular tachyarrhythmias and appropriate ICD therapies in a high-risk ICD population.

Authors:  Tobias Schupp; Ibrahim Akin; Linda Reiser; Armin Bollow; Gabriel Taton; Thomas Reichelt; Dominik Ellguth; Niko Engelke; Uzair Ansari; Kambis Mashayekhi; Christel Weiß; Christoph Nienaber; Muharrem Akin; Martin Borggrefe; Michael Behnes
Journal:  Clin Res Cardiol       Date:  2019-02-12       Impact factor: 5.460

2.  [Severe ventricular arrhythmias in a patient with dilated cardiomyopathy and automated implantable defibrillator (AID)].

Authors:  Stéphane Méo Ikama; Jospin Makani; Bertrand Ellenga-Mbolla; Louis Igor Ondze-Kafata; Thierry Raoul Gombet; Gisèle Kimbally-Kaky
Journal:  Pan Afr Med J       Date:  2017-05-11

3.  Comparison of ventricular tachyarrhythmia recurrence between ischemic cardiomyopathy and dilated cardiomyopathy: a retrospective study.

Authors:  Chih-Yuan Fang; Huang-Chung Chen; Yung-Lung Chen; Tzu-Hsien Tsai; Kuo-Li Pan; Yu-Sheng Lin; Mien-Cheng Chen; Wei-Chieh Lee
Journal:  PeerJ       Date:  2018-07-16       Impact factor: 2.984

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.