Personal and psychosocial factors and symptoms compatible with sick building syndrome in the Swedish workforce.

R Runeson1, K Wahlstedt, G Wieslander, D Norbäck.   

Abstract

A random sample of 1000 subjects (20-65 years of age) received a postal questionnaire regarding sick building syndrome (SBS), including the three-dimensional model of demand-control-support (DCS). The response rate was 70% (n = 695), and 532 were occupationally active. Female gender and atopy were the main predictors of symptoms. Eye symptoms were more common at low social support combined with strained work situation [odds ratio (OR) 2.37], and at high social support combined with active work situation (OR 3.00). Throat symptoms were more common at low social support combined with either passive (OR 1.86) or strained situation (OR 2.42). Tiredness was more common at low social support combined with either passive (OR 2.41), strained (OR 2.25), or active situation (OR 1.87), and at high social support combined with active work situation (OR 1.83). Low social support combined with either passive (P = 0.01) or strained job situation (P = 0.01) was associated with a higher symptom score (SC). The lowest SC was found at a relaxed work situation, irrespective of social support. In conclusion, female gender, low age, asthma, atopy and psychosocial work environment are associated with symptoms. The three-dimensional model can predict symptoms compatible with SBS, but in a more complex way than earlier research indicated. Practical Implications A multi-disciplinary approach, including psychosocial stress factors as well as personal factors such as gender, age, atopy and asthma, and indoor exposures, should be applied in studies on symptoms compatible with sick building syndrome (SBS). Males and females perceive psychosocial work conditions differently, and may react differently to job stressors. The psychosocial work environment can be as important as gender and atopy as a predictor of SBS symptoms.

Entities:  

Mesh:

Year:  2006        PMID: 17100665     DOI: 10.1111/j.1600-0668.2006.00438.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  17 in total

1.  Relation of dampness to sick building syndrome in Japanese public apartment houses.

Authors:  Yasuaki Saijo; Yoshihiko Nakagi; Toshihiro Ito; Yoshihiko Sugioka; Hitoshi Endo; Takahiko Yoshida
Journal:  Environ Health Prev Med       Date:  2008-10-24       Impact factor: 3.674

2.  Analysis of the indoor environment of agricultural constructions in the context of sustainability.

Authors:  Jozef Švajlenka; Mária Kozlovská; Terézia Pošiváková
Journal:  Environ Monit Assess       Date:  2019-07-10       Impact factor: 2.513

3.  Sick building syndrome (SBS) and sick house syndrome (SHS) in relation to psychosocial stress at work in the Swedish workforce.

Authors:  Roma Runeson-Broberg; Dan Norbäck
Journal:  Int Arch Occup Environ Health       Date:  2012-11-11       Impact factor: 3.015

4.  Asthma related to workplace dampness and impaired work ability.

Authors:  Kirsi Karvala; Henrik Nordman; Ritva Luukkonen; Jukka Uitti
Journal:  Int Arch Occup Environ Health       Date:  2012-12-04       Impact factor: 3.015

5.  Dampness, food habits, and sick building syndrome symptoms in elementary school pupils.

Authors:  Yasuaki Saijo; Yoshihiko Nakagi; Toshihiro Ito; Yoshihiko Sugioka; Hitoshi Endo; Takahiko Yoshida
Journal:  Environ Health Prev Med       Date:  2010-03-26       Impact factor: 3.674

6.  Effect of Traffic Exposure on Sick Building Syndrome Symptoms among Parents/Grandparents of Preschool Children in Beijing, China.

Authors:  Linyan Li; Gary Adamkiewicz; Yinping Zhang; John D Spengler; Fang Qu; Jan Sundell
Journal:  PLoS One       Date:  2015-06-18       Impact factor: 3.240

7.  Odors and sensations of humidity and dryness in relation to sick building syndrome and home environment in Chongqing, China.

Authors:  Juan Wang; Baizhan Li; Qin Yang; Wei Yu; Han Wang; Dan Norback; Jan Sundell
Journal:  PLoS One       Date:  2013-08-26       Impact factor: 3.240

8.  Allostatic load model associated with indoor environmental quality and sick building syndrome among office workers.

Authors:  Chien-Cheng Jung; Hsiu-Hao Liang; Hui-Ling Lee; Nai-Yun Hsu; Huey-Jen Su
Journal:  PLoS One       Date:  2014-04-23       Impact factor: 3.240

9.  Personal, Psychosocial and Environmental Factors Related to Sick Building Syndrome in Official Employees of Taiwan.

Authors:  Chung-Yen Lu; Meng-Chuan Tsai; Chih-Hsin Muo; Yu-Hsien Kuo; Fung-Chang Sung; Chin-Ching Wu
Journal:  Int J Environ Res Public Health       Date:  2017-12-22       Impact factor: 3.390

Review 10.  Assessment of Indoor Air Quality Problems in Office-Like Environments: Role of Occupational Health Services.

Authors:  Paolo Carrer; Peder Wolkoff
Journal:  Int J Environ Res Public Health       Date:  2018-04-12       Impact factor: 3.390