Literature DB >> 17100372

Effect of halogen light in fetal stimulation for fetal well-being assessment.

Isarin Thanaboonyawat1, Tuangsit Wataganara, Dittakarn Boriboonhiransarn, Sommai Viboonchart, Pornpen Tontisirin.   

Abstract

OBJECTIVE: To evaluate the shortening of the time of nonstress test (NST) by using transabdominal fetal stimulation with halogen light. STUDY
DESIGN: Experimental research. MATERIAL AND
METHOD: The authors enrolled 176 pregnant women between 32 and 42 weeks of gestation indicated for NST at the Division of Maternal Fetal Medicine, Siriraj Hospital, Mahidol University. They were randomly assigned to receive either NST (control) or halogen light stimulation test (LST). The stimulation was performed at the beginning of the test and repeated every 10 minutes until reassuring fetal heart rate (FHR) acceleration was achieved, or up to 3 times. All tracings were interpreted blindly by one investigator at the end of the tests.
RESULTS: The mean (+/- SD) duration from starting the test to the first FHR acceleration was not significantly different between the control group and the LST group (5.6 +/- 7.2 and 5.4 +/- 5.2 minutes, respectively). The average testing time (+/- SD) to achieved reactivity was 10.5 +/- 8.8 minutes in the controls and 9.6 +/- 6.7 minutes in the LST group. This was not statistically different. The incidence of nonreactive tests was not significantly different between the LST and the controls (15.9% and 11.4%, respectively). Among the LST subjects, term fetuses and women with BMI < 27 kg/m2 required less time to reach reactivity, 2.4 and 2.3 minutes respectively.
CONCLUSION: Transabdominal halogen light stimulation did not shorten the duration of NST in the presented population. However, the presented data suggests that the fetus at term could respond to visual stimulation, especially when the gestational age is more advanced.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17100372

Source DB:  PubMed          Journal:  J Med Assoc Thai        ISSN: 0125-2208


  3 in total

1.  The effect of halogen light stimulation on duration of ultrasound parameters of biophysical profile: a randomized clinical trial.

Authors:  Mohammad Ghasem Hanafi; Aliakbar Sahraeizadeh
Journal:  J Med Ultrason (2001)       Date:  2018-02-22       Impact factor: 1.314

2.  Comparison of halogen light and vibroacoustic stimulation on nonreactive fetal heart rate pattern.

Authors:  Fatemeh Rahimikian; Tahereh Rahiminia; Maryam Modarres; Abbas Mehran
Journal:  Iran J Nurs Midwifery Res       Date:  2013-03

Review 3.  Retinogenesis of the Human Fetal Retina: An Apical Polarity Perspective.

Authors:  Peter M J Quinn; Jan Wijnholds
Journal:  Genes (Basel)       Date:  2019-11-29       Impact factor: 4.096

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.