Literature DB >> 17097671

Selective analysis of histamine in food by means of solid-phase extraction cleanup and chromatographic separation.

Shigeyuki Oguri1, Mayo Enami, Naoko Soga.   

Abstract

A simple, practical technique is presented for the selective determination and measurement of histamine (HA) levels in fermented food. The method involved a solid-phase extraction cleanup using a Sep-Pak Plus C-18 cartridge and ion-paired reversed-phase high-performance liquid chromatographic (IP-RP-HPLC) separation, followed by detection of HA at its UV absorbance wavelength of 220nm. After evaporating a methanolic extract from the food sample, the resulting residue was reconstituted with 0.2M phosphate buffer (pH 3.0), and subsequently passed through the cartridge. The aliquot of the solution which came out of the cartridge was chromatographed in IP-RP mode on a C-18 column, as the stationary phase, and with a solution of 0.2M phosphate buffer (pH 3.0)-acetonitrile-water (1:24:166, v/v) containing 2mM sodium 1-octane sulfonic acid, as the mobile phase. When this method was applied to a mixture of HA, Cadaverine (Cad), Putrescine (Put), Serotonin (5HT), and Tyramine (Tyr), only HA was detected at 16.4min of retention time. The method was fully validated and validation parameters were: linearity range 2-1000ppm; correlation coefficient >0.991; mean recovery >99.5%; limit of quantification 2ppm and limit of detection 0.5ppm. The method was next applied to 12 brands of Miso (fermented soybean paste), 9 brands of Sake (rice wine), and 5 brands of Shouyu (Japanese soy sauce) to verify its ability to detect the presence of HA in a variety of fermented foods. The method proved to be both rapid and accurate and is therefore recommended for use in HA pollution surveys and in the routine practice of food-quality control.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17097671     DOI: 10.1016/j.chroma.2006.10.077

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Electrochemical sensing of histamine using a glassy carbon electrode modified with multiwalled carbon nanotubes decorated with Ag-Ag2O nanoparticles.

Authors:  Nutthaya Butwong; Jariya Khajonklin; Atitaya Thongbor; John H T Luong
Journal:  Mikrochim Acta       Date:  2019-10-25       Impact factor: 5.833

2.  Improved HPLC Method Using 2,3-naphthalenedicarboxaldehyde as Fluorescent Labeling Agent for Quantification of Histamine in Human Immunoglobulin Preparations.

Authors:  Jung-Hwan Kim; In Soo Shin; Yoo Kyoung Lee; Ho Jung Oh; Sang Ja Ban
Journal:  Osong Public Health Res Perspect       Date:  2011-07-29

3.  Quality evaluation of living and postmortem Chinese mitten crabs (Eriocheir sinensis).

Authors:  Yahui Wang; Yaozhou Zhu; Wenzheng Shi; Xichang Wang
Journal:  Food Sci Nutr       Date:  2020-04-17       Impact factor: 2.863

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.