Literature DB >> 17096267

Characterizing occipital condyle loads under high-speed head rotation.

Frank A Pintar1, Narayan Yoganandan, Jamie Baisden.   

Abstract

Because of the need to evaluate anthropomorphic test device (ATD) biofidelity under high-head angular accelerations, the purpose of the present investigation was to develop appropriate instrumentation for intact post mortem human subject (PMHS) testing, validate the instrumentation, and obtain information to characterize the response of the head-neck complex under this loading scenario. A series of rigid-arm pendulum, inertially loaded ATD tests was conducted. Head and neck ATD hydraulic piston chin pull tests were conducted. Subsequently, a series of PMHS tests was conducted to derive the response of the human head-neck under high-rate chin loading. Finally, Hybrid III and THOR-NT ATD head-neck systems were evaluated under the same scenario as the PMHS. A parametric analysis for center of gravity (CG) location and accelerometer orientation determined that even small errors (+/- 3 mm or 2 degrees), produced errors in the force and moment calculations by as much as 17 %. If the moment of inertia (MOI) term was varied by 5 %, resulting moment calculations were affected by as much as 8 %. If the 5 % error in MOI was used to compute occipital condyle moments, and results compared to upper load cell derived moments, peaks differed by as much as 24 %. The head CG and mass MOI should be directly measured for each preparation to obtain accurate results. The injury run on each specimen resulted in predominantly C1-C2 separations or partial separations. The 50(th) percentile probability of AIS=2+ neck injury using tensile force was about 2400 N; for AIS=3+ neck injury the 50(th) percentile risk was about 3180 N. When inserting extension moment as the criteria, the 50(th) percentile probability of an AIS=2+ injury was 51 Nm. The AIS=3+ extension moment at the 50(th) percentile probability was 75 Nm. The new THOR-NT ATD head-neck produced more biofidelic responses with an alternate head-neck junction design compared to the Hybrid III ATD.

Entities:  

Year:  2005        PMID: 17096267     DOI: 10.4271/2005-22-0002

Source DB:  PubMed          Journal:  Stapp Car Crash J        ISSN: 1532-8546


  4 in total

1.  Subject-specific inverse dynamics of the head and cervical spine during in vivo dynamic flexion-extension.

Authors:  William J Anderst; William F Donaldson; Joon Y Lee; James D Kang
Journal:  J Biomech Eng       Date:  2013-06       Impact factor: 2.097

2.  Influence of head mass on temporo-parietal skull impact using finite element modeling.

Authors:  Debasis Sahoo; Caroline Deck; Narayan Yoganandan; Rémy Willinger
Journal:  Med Biol Eng Comput       Date:  2015-04-12       Impact factor: 2.602

3.  Lateral neck injury assessments in side impact using post mortem human subject tests.

Authors:  Narayan Yoganandan; John Humm; Frank A Pintar; Christopher E Wolfla; Dennis J Maiman
Journal:  Ann Adv Automot Med       Date:  2011

4.  Effects of different severities of disc degeneration on the range of motion of cervical spine.

Authors:  Narayan Yoganandan; Hoon Choi; Yuvaraj Purushothaman; Davidson Jebaseelan; Jamie Baisden; Shekar Kurpad
Journal:  J Craniovertebr Junction Spine       Date:  2020-11-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.