Literature DB >> 17092159

Reliability of the compensation comparison method for measuring retinal stray light studied using Monte-Carlo simulations.

Joris E Coppens1, Luuk Franssen, Thomas J T P van den Berg.   

Abstract

Recently the psychophysical compensation comparison method was developed for routine measurement of retinal stray light. The subject's responses to a series of two-alternative-forced-choice trials are analyzed using a maximum-likelihood (ML) approach assuming some fixed shape for the psychometric function (PF). This study evaluates the reliability of the method using Monte-Carlo simulations. Various sampling strategies were investigated, including the two-phase sampling strategy that is used in a commercially available instrument. Results are given for the effective dynamic range and measurement accuracy. The effect of a mismatch of the shape of the PF of an observer and the fixed shape used in the ML analysis was analyzed. Main outcomes are that the two-phase sampling scheme gives good precision (Standard deviation = 0.07 logarithmic units on average) for estimation of the stray light value. Bias is virtually zero. Furthermore, a reliability index was derived from the responses and found to be effective.

Mesh:

Year:  2006        PMID: 17092159     DOI: 10.1117/1.2357731

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  4 in total

1.  Performance of a differential contrast sensitivity method to measure intraocular scattering.

Authors:  Alexandros Pennos; Harilaos Ginis; Augusto Arias; Dimitrios Christaras; Pablo Artal
Journal:  Biomed Opt Express       Date:  2017-02-06       Impact factor: 3.732

2.  Reproducibility of straylight measurement by C-Quant for assessment of retinal straylight using the compensation comparison method.

Authors:  Ivo Guber; Lucas M Bachmann; Josef Guber; Frank Bochmann; Alex P Lange; Michael A Thiel
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-05-13       Impact factor: 3.117

3.  Repeatability, Reproducibility, and Comparability of Subjective and Objective Measurements of Intraocular Forward Scattering in Healthy Subjects.

Authors:  Ayaka Iijima; Kimiya Shimizu; Hidenaga Kobashi; Aya Saito; Kazutaka Kamiya
Journal:  Biomed Res Int       Date:  2015-06-14       Impact factor: 3.411

4.  South American Values of the Optical Straylight Function.

Authors:  Emilia Longhi Bitencourt; Dora Fix Ventura; Marcelo Fernandes Costa
Journal:  Vision (Basel)       Date:  2019-12-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.