Literature DB >> 17091852

Subharmonic emissions from microbubbles: effect of the driving pulse shape.

Elena Biagi, Luca Breschi, Enrico Vannacci, Leonardo Masotti.   

Abstract

The aims of this work are to investigate the response of the ultrasonic contrast agents (UCA) insonified by different arbitrary-shaped pulses at different acoustic pressures and concentration of the contrast agent focusing on subharmonic emission. A transmission setup was developed in order to insonify the contrast agent contained in a measurement chamber. The transmitted ultrasonic signals were generated by an arbitrary wave generator connected to a linear power amplifier able to drive a single-element transducer. The transmitted ultrasonic pulses that passed through the contrast agent-filled chamber were received by a second transducer or a hydrophone aligned with the first one. The radio frequency (RF) signals were acquired by fast echographic multiparameters multi-image novel apparatus (FEMMINA), which is an echographic platform able to acquire ultrasonic signals in a real-time modality. Three sets of ultrasonic signals were devised in order to evaluate subharmonic response of the contrast agent respect with sinusoidal burst signals used as reference pulses. A decreasing up to 30 dB in subharmonic response was detected for a Gaussian-shaped pulse; differences in subharmonic emission up to 21 dB were detected for a composite pulse (two-tone burst) for different acoustic pressures and concentrations. Results from this experimentation demonstrated that the transmitted pulse shape strongly affects subharmonic emission in spite of a second harmonic one. In particular, the smoothness of the initial portion of the shaped pulses can inhibit subharmonic generation from the contrast agents respect with a reference sinusoidal burst signal. It also was shown that subharmonic generation is influenced by the amplitude and the concentration of the contrast agent for each set of the shaped pulses. Subharmonic emissions that derive from a nonlinear mechanism involving nonlinear coupling among different oscillation modes are strongly affected by the shape of the ultrasonic driving pulse.

Mesh:

Substances:

Year:  2006        PMID: 17091852     DOI: 10.1109/tuffc.2006.157

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  4 in total

1.  Improving the sensitivity of high-frequency subharmonic imaging with coded excitation: a feasibility study.

Authors:  Himanshu Shekhar; Marvin M Doyley
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Modifying the size distribution of microbubble contrast agents for high-frequency subharmonic imaging.

Authors:  Himanshu Shekhar; Joshua J Rychak; Marvin M Doyley
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

3.  Effect of Pulse Shaping on Subharmonic Aided Pressure Estimation In Vitro and In Vivo.

Authors:  Ipshita Gupta; John Eisenbrey; Maria Stanczak; Anush Sridharan; Jaydev K Dave; Ji-Bin Liu; Christopher Hazard; Xinghua Wang; Ping Wang; Huiwen Li; Kirk Wallace; Flemming Forsberg
Journal:  J Ultrasound Med       Date:  2016-12-10       Impact factor: 2.153

4.  Transrectal Subharmonic Ultrasound Imaging for Prostate Cancer Detection.

Authors:  I Gupta; B Freid; V Masarapu; P Machado; E Trabulsi; K Wallace; E Halpern; F Forsberg
Journal:  Urology       Date:  2019-12-30       Impact factor: 2.649