Literature DB >> 17089846

Massive-training artificial neural network (MTANN) for reduction of false positives in computer-aided detection of polyps: Suppression of rectal tubes.

Kenji Suzuki1, Hiroyuki Yoshida, Janne Näppi, Abraham H Dachman.   

Abstract

One of the limitations of the current computer-aided detection (CAD) of polyps in CT colonography (CTC) is a relatively large number of false-positive (FP) detections. Rectal tubes (RTs) are one of the typical sources of FPs because a portion of a RT, especially a portion of a bulbous tip, often exhibits a cap-like shape that closely mimics the appearance of a small polyp. Radiologists can easily recognize and dismiss RT-induced FPs; thus, they may lose their confidence in CAD as an effective tool if the CAD scheme generates such "obvious" FPs due to RTs consistently. In addition, RT-induced FPs may distract radiologists from less common true positives in the rectum. Therefore, removal RT-induced FPs as well as other types of FPs is desirable while maintaining a high sensitivity in the detection of polyps. We developed a three-dimensional (3D) massive-training artificial neural network (MTANN) for distinction between polyps and RTs in 3D CTC volumetric data. The 3D MTANN is a supervised volume-processing technique which is trained with input CTC volumes and the corresponding "teaching" volumes. The teaching volume for a polyp contains a 3D Gaussian distribution, and that for a RT contains zeros for enhancement of polyps and suppression of RTs, respectively. For distinction between polyps and nonpolyps including RTs, a 3D scoring method based on a 3D Gaussian weighting function is applied to the output of the trained 3D MTANN. Our database consisted of CTC examinations of 73 patients, scanned in both supine and prone positions (146 CTC data sets in total), with optical colonoscopy as a reference standard for the presence of polyps. Fifteen patients had 28 polyps, 15 of which were 5-9 mm and 13 were 10-25 mm in size. These CTC cases were subjected to our previously reported CAD scheme that included centerline-based segmentation of the colon, shape-based detection of polyps, and reduction of FPs by use of a Bayesian neural network based on geometric and texture features. Application of this CAD scheme yielded 96.4% (27/28) by-polyp sensitivity with 3.1 (224/73) FPs per patient, among which 20 FPs were caused by RTs. To eliminate the FPs due to RTs and possibly other normal structures, we trained a 3D MTANN with ten representative polyps and ten RTs, and applied the trained 3D MTANN to the above CAD true- and false-positive detections. In the output volumes of the 3D MTANN, polyps were represented by distributions of bright voxels, whereas RTs and other normal structures partly similar to RTs appeared as darker voxels, indicating the ability of the 3D MTANN to suppress RTs as well as other normal structures effectively. Application of the 3D MTANN to the CAD detections showed that the 3D MTANN eliminated all RT-induced 20 FPs, as well as 53 FPs due to other causes, without removal of any true positives. Overall, the 3D MTANN was able to reduce the FP rate of the CAD scheme from 3.1 to 2.1 FPs per patient (33% reduction), while the original by-polyp sensitivity of 96.4% was maintained.

Entities:  

Mesh:

Year:  2006        PMID: 17089846     DOI: 10.1118/1.2349839

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  20 in total

Review 1.  Improving the accuracy of CTC interpretation: computer-aided detection.

Authors:  Ronald M Summers
Journal:  Gastrointest Endosc Clin N Am       Date:  2010-04

2.  Medical image analysis: computer-aided diagnosis of gastric cancer invasion on endoscopic images.

Authors:  Keisuke Kubota; Junko Kuroda; Masashi Yoshida; Keiichiro Ohta; Masaki Kitajima
Journal:  Surg Endosc       Date:  2011-11-15       Impact factor: 4.584

Review 3.  Anniversary paper: History and status of CAD and quantitative image analysis: the role of Medical Physics and AAPM.

Authors:  Maryellen L Giger; Heang-Ping Chan; John Boone
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

4.  Automated breast mass detection in 3D reconstructed tomosynthesis volumes: a featureless approach.

Authors:  Swatee Singh; Georgia D Tourassi; Jay A Baker; Ehsan Samei; Joseph Y Lo
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

5.  Machine Learning in Computer-aided Diagnosis of the Thorax and Colon in CT: A Survey.

Authors:  Kenji Suzuki
Journal:  IEICE Trans Inf Syst       Date:  2013-04-01

6.  CT colonography: advanced computer-aided detection scheme utilizing MTANNs for detection of "missed" polyps in a multicenter clinical trial.

Authors:  Kenji Suzuki; Don C Rockey; Abraham H Dachman
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

7.  Improved computer-aided detection of small polyps in CT colonography using interpolation for curvature estimation.

Authors:  Jiamin Liu; Suraj Kabadi; Robert Van Uitert; Nicholas Petrick; Rachid Deriche; Ronald M Summers
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

8.  Computer-aided diagnosis systems for lung cancer: challenges and methodologies.

Authors:  Ayman El-Baz; Garth M Beache; Georgy Gimel'farb; Kenji Suzuki; Kazunori Okada; Ahmed Elnakib; Ahmed Soliman; Behnoush Abdollahi
Journal:  Int J Biomed Imaging       Date:  2013-01-29

9.  Optimizing computer-aided colonic polyp detection for CT colonography by evolving the Pareto fronta.

Authors:  Jiang Li; Adam Huang; Jack Yao; Jiamin Liu; Robert L Van Uitert; Nicholas Petrick; Ronald M Summers
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

10.  A review of computer-aided diagnosis in thoracic and colonic imaging.

Authors:  Kenji Suzuki
Journal:  Quant Imaging Med Surg       Date:  2012-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.