The axial misalignment between ocular lens and cornea observed by MRI (I)--at fixed accommodative state.

Yin Chang1, Hsiu-Mei Wu, Yu-Fong Lin.   

Abstract

Lens tilt and decentration relative to the corneal axis are two of the factors which cause aberration in human eyes. Although many techniques have been developed to quantitatively measure these factors, however, they are mostly confined in 2D observations. To extend the view from 2D to 3D, MR imaging technique becomes a good candidate due to its capability of 3D-image reconstruction and with fairly good spatial resolution for that purpose. In this study a total of six eyes of six young students at this Institute were examined by using a 1.5T MRI machine incorporating with a commercial 3-in. surface coil at Taipei Veterans General Hospital. From a 45 degrees flipped reflective mirror, the subject could focus to a target at a distance of 60 cm from the eye for MR imaging in monocular vision. Quadric surface models were used to fit cornea and lens surfaces in the post image processes. Tilts of the two lens surfaces and the decentration of lens centre with respect to corneal axis were determined through coordinate transformations. One month later, retest was carried out on five of the six subjects. The results show that the average tilts of anterior and posterior lens surfaces, and lens decentration are 3.7+/-2.5 degrees, 3.3+/-1.4 degrees and 0.11+/-0.07 mm (H), -0.06+/-0.38 mm (V), respectively, for the test; 2.1+/-2.4 degrees, 1.9+/-1.8 degrees and -0.02+/-0.28 mm (H), -0.45+/-0.28 mm (V) for the retest. No statistically significant difference (by Wilcoxon Signed Ranks test) is revealed for the tilts of both lens surfaces (p(phia)=0.375, p(phip)=0.225) and for decentration (p(H)=0.343, p(V)=0.345) between test and retest in this longitudinal observation. The surface shapes of the ocular anterior components do not seem to be unified by only one type but ellipsoid, elliptic paraboloid, hyperboloid and paraboloid are all possible. Changes in shape type in the ocular anterior components were also found when measured in a period of one month.

Entities:  

Mesh:

Year:  2006        PMID: 17084432     DOI: 10.1016/j.visres.2006.09.018

Source DB:  PubMed          Journal:  Vision Res        ISSN: 0042-6989            Impact factor:   1.886


  4 in total

1.  A Geometric Theory Integrating Human Binocular Vision With Eye Movement.

Authors:  Jacek Turski
Journal:  Front Neurosci       Date:  2020-12-07       Impact factor: 4.677

2.  Comparing low-coherence interferometry and A-scan ultrasonography in measuring ocular axial dimensions in young rhesus monkeys.

Authors:  Zhihui She; Li-Fang Hung; Krista M Beach; Baskar Arumugam; Earl L Smith; Lisa A Ostrin
Journal:  Exp Eye Res       Date:  2022-01-22       Impact factor: 3.467

3.  Retinal magnification factors at the fixation locus derived from schematic eyes with four individualized surfaces.

Authors:  Xiaojing Huang; Trevor Anderson; Alfredo Dubra
Journal:  Biomed Opt Express       Date:  2022-06-08       Impact factor: 3.562

4.  Determinants of intraocular lens tilt and decentration after cataract surgery.

Authors:  Xiaoxun Gu; Xiaoyun Chen; Guangyao Yang; Wei Wang; Wei Xiao; Guangming Jin; Lanhua Wang; Ye Dai; Xiaoting Ruan; Zhenzhen Liu; Lixia Luo; Yizhi Liu
Journal:  Ann Transl Med       Date:  2020-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.