Literature DB >> 35074342

Comparing low-coherence interferometry and A-scan ultrasonography in measuring ocular axial dimensions in young rhesus monkeys.

Zhihui She1, Li-Fang Hung2, Krista M Beach1, Baskar Arumugam3, Earl L Smith2, Lisa A Ostrin4.   

Abstract

We investigated a commercial low-coherence interferometer (LenStar LS 900 optical biometer) in measuring young rhesus monkey ocular dimensions. Ocular biometry data obtained using a LenStar and an A-scan ultrasound instrument (OPT-scan 1000) from 163 rhesus monkeys during 20-348 days of age were compared by means of coefficients of concordance and 95% limits of agreement. Linear regression was employed to examine and analyze the inter-instrument discrepancies. In young rhesus monkeys, the test-retest reliability of the LenStar was equal to or exceeded that of A-scan ultrasound (intraclass correlation = 0.86 to 0.93). The inter-instrument agreement was strong for vitreous chamber depth and axial length (coefficient of concordance = 0.95 and 0.86, respectively) and moderate for anterior chamber depth and lens thickness (coefficient of concordance = 0.74 and 0.63, respectively). The LenStar systematically underestimated ocular dimensions when compared to A-scan ultrasound (mean magnitude of difference = 0.11-0.57 mm). This difference could be minimized using linear calibration functions to equate LenStar data with ultrasound data. When this method was applied, the values between instruments were in excellent absolute agreement (mean magnitude of difference = 0.004-0.01 mm). In conclusion, the LenStar reliably measured ocular dimensions in young monkeys. When an appropriate calibration function is applied, the LenStar can be used as a substitute for A-scan ultrasonography.
Copyright © 2022 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Acoustic property; LenStar; Ocular axial dimensions; Refractive indices; Rhesus monkeys; Ultrasonography

Mesh:

Year:  2022        PMID: 35074342      PMCID: PMC8957592          DOI: 10.1016/j.exer.2022.108937

Source DB:  PubMed          Journal:  Exp Eye Res        ISSN: 0014-4835            Impact factor:   3.467


  40 in total

Review 1.  Statistical techniques for comparing measurers and methods of measurement: a critical review.

Authors:  John Ludbrook
Journal:  Clin Exp Pharmacol Physiol       Date:  2002-07       Impact factor: 2.557

2.  Use and misuse of the reduced major axis for line-fitting.

Authors:  Richard J Smith
Journal:  Am J Phys Anthropol       Date:  2009-11       Impact factor: 2.868

3.  Ultrasonography and optical low-coherence interferometry compared in the chicken eye.

Authors:  Alexandra Marcha Penha; Eva Burkhardt; Frank Schaeffel; Marita P Feldkaemper
Journal:  Optom Vis Sci       Date:  2012-06       Impact factor: 1.973

4.  Non-invasive phakometric measurement of corneal and crystalline lens alignment in human eyes.

Authors:  Mark C M Dunne; Leon N Davies; Edward A H Mallen; Thomas Kirschkamp; Jean-Cyriaque Barry
Journal:  Ophthalmic Physiol Opt       Date:  2005-03       Impact factor: 3.117

5.  Biometric investigation of changes in the anterior eye segment during accommodation.

Authors:  W Drexler; A Baumgartner; O Findl; C K Hitzenberger; A F Fercher
Journal:  Vision Res       Date:  1997-10       Impact factor: 1.886

6.  A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.

Authors:  Terry K Koo; Mae Y Li
Journal:  J Chiropr Med       Date:  2016-03-31

7.  Slit-lamp studies of the rhesus monkey eye: II. Changes in crystalline lens shape, thickness and position during accommodation and aging.

Authors:  J F Koretz; A M Bertasso; M W Neider; B A True-Gabelt; P L Kaufman
Journal:  Exp Eye Res       Date:  1987-08       Impact factor: 3.467

8.  Comparison of A-Scan ultrasonography and the Lenstar optical biometer in Guinea pig eyes.

Authors:  Qiong Wang; Xiaowen Ji; Daqian Lu; Ying Zhu; Amy Whelchel; Jingyi Wang; Hongmei Zhang; Lijie Dong; Ruihua Wei
Journal:  Exp Eye Res       Date:  2021-04-20       Impact factor: 3.467

9.  Matching the LenStar optical biometer to A-Scan ultrasonography for use in small animal eyes with application to tree shrews.

Authors:  Mustapha El Hamdaoui; Drew W Gann; Thomas T Norton; Rafael Grytz
Journal:  Exp Eye Res       Date:  2018-12-27       Impact factor: 3.467

10.  Anterior Segment Biometry with Phenylephrine and Tropicamide during Accommodation Imaged with Ultralong Scan Depth Optical Coherence Tomography.

Authors:  Junna Zhang; Yang Ni; Peng Li; Wen Sun; Mengyun Liu; Dongyu Guo; Chixin Du
Journal:  J Ophthalmol       Date:  2019-02-25       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.