Literature DB >> 17081864

In vivo architectural analysis of 3.2 mm clear corneal incisions for phacoemulsification using optical coherence tomography.

Luis F Torres1, Fidelia Saez-Espinola, Juner M Colina, Myriam Retchkiman, Milan R Patel, Ricardo Agurto, Gerardo Garcia, Jose L Diaz, David Huang, David J Schanzlin, Arturo S Chayet.   

Abstract

PURPOSE: To analyze in vivo the architecture of clear corneal incisions (CCIs) for phacoemulsification using optical coherence tomography (OCT).
SETTING: Anterior Segment Department, Asociacion Para Evitar la Ceguera en Mexico, Hospital Dr Luis Sanchez Bulnes, Mexico.
METHODS: A prospective masked study analyzed 20 unsutured CCIs placed superiorly and created in a uniplanar fashion with a 3.2 mm slit-angled metal keratome. All wounds were evaluated with a retinal OCT model 1, 3, and 30 days postoperatively. Intraocular pressure (IOP) and incision leakage were checked. The architecture was described according to the angle of incidence, apposition of the epithelial and endothelial margins, and wound sealing.
RESULTS: No leakage was detected. The angle varied from 33 to 85 degrees; angles greater than 75 degrees were done by a surgeon in training. Wound apposition at the epithelial margin was achieved in all cases. In contrast, imperfect apposition of the endothelial margin was seen in 45% of incisions on day 1 and in 15% on day 30. Incomplete sealing of the wound was seen by OCT in 25% of cases at 24 hours and persisted in 10% of all cases at 1 month. This gaping occurred on the endothelial side and never translated to the epithelial margin. No statistical correlation was found between gaping and the angle of the incision, IOP variations, or surgeon experience.
CONCLUSIONS: Although in vivo CCIs caused minor anatomic imperfections, they were clinically stable independent of incision angle, IOP variation, and surgeon experience. Incision stability may be related to careful wound construction, epithelial viability, stromal edema, and efficient endothelial pumping.

Entities:  

Mesh:

Year:  2006        PMID: 17081864     DOI: 10.1016/j.jcrs.2006.06.020

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  10 in total

Review 1.  [Incisions for biaxial and coaxial microincision cataract surgery].

Authors:  M Müller; T Kohnen
Journal:  Ophthalmologe       Date:  2010-02       Impact factor: 1.059

2.  Staging of development in Terrien's degeneration based on corneal curvatures detected by optical coherence tomography.

Authors:  Ning Wang; Chun-Xiao Wang; Xiu-Fen Lian; Su-Juan Duan; David Huang; Shi-You Zhou
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-05-21       Impact factor: 3.117

3.  Early changes in corneal edema following torsional phacoemulsification using anterior segment optical coherence tomography and Scheimpflug photography.

Authors:  Ying-Jun Li; Hyo-Jin Kim; Choun-Ki Joo
Journal:  Jpn J Ophthalmol       Date:  2011-05-11       Impact factor: 2.447

4.  OCT-documented incision features and natural history of clear corneal incisions used for bimanual microincision cataract surgery.

Authors:  Graham W Lyles; Kenneth L Cohen; Diana Lam
Journal:  Cornea       Date:  2011-06       Impact factor: 2.651

5.  Comparison of new motorized injector vs manual injector for implantation of foldable intraocular lenses on wound integrity: an ASOCT study.

Authors:  S Khokhar; R Sharma; B Patil; N Aron; S Gupta
Journal:  Eye (Lond)       Date:  2014-07-18       Impact factor: 3.775

6.  Optical coherence tomography of clear corneal incisions for cataract surgery.

Authors:  Julie M Schallhorn; Maolong Tang; Yan Li; Jonathan C Song; David Huang
Journal:  J Cataract Refract Surg       Date:  2008-09       Impact factor: 3.351

7.  Structural analysis of different incision sizes and stromal hydration in cataract surgery using anterior segment optical coherence tomography.

Authors:  Jong-Wook Bang; Jong-Hyun Lee; Jin-Hyoung Kim; Do-Hyung Lee
Journal:  Korean J Ophthalmol       Date:  2015-01-22

8.  Wound Integrity of 2.0 mm Transconjunctival Single-Plane Sclerocorneal Incision: A Comparison between a Motorized Injector with/without Pause Time and a Manual Injector.

Authors:  Hisanori Imai; Ayaka Fujii; Emiko Tani; Atsushi Azumi
Journal:  J Ophthalmol       Date:  2016-02-17       Impact factor: 1.909

9.  Architecture evaluation of the main clear corneal incisions in femtosecond laser-assisted cataract surgery by optical coherence tomography imaging.

Authors:  Mario Augusto Pereira Dias Chaves; André Lins de Medeiros; César Martins Cortez Vilar; Klayne Rafaella Pereira Magalhães; Michelle Rodrigues Gonçalves; Patrick Frenzel de Moraes Tzelikis; Wilson Takashi Hida; Pedro Carlos Carricondo; Milton Ruiz Alves
Journal:  Clin Ophthalmol       Date:  2019-02-14

10.  Intracameral air injection after completion of phacoemulsification cataract surgery: Evaluation of corneal incisions with optical coherence tomography.

Authors:  Erdem Yuksel; Mehmet Ozgur Cubuk; Kubra Serbest Ceylanoglu
Journal:  J Curr Ophthalmol       Date:  2019-02-13
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.