Literature DB >> 17081212

Newly detected atrial fibrillation following dual chamber pacemaker implantation.

Jim W Cheung1, Richard J Keating, Kenneth M Stein, Steven M Markowitz, Sei Iwai, Bindi K Shah, Bruce B Lerman, Suneet Mittal.   

Abstract

INTRODUCTION: Pacemaker (PPM)-detected atrial high-rate episodes (AHREs) of even 5-minute duration may identify patients at increased risk for stroke and death. In this study, we sought to determine the incidence of newly detected atrial fibrillation (AF defined as an AHRE > or = 5 minutes) in patients following dual-chamber PPM implantation and to define the clinical predictors of developing AF. METHODS AND
RESULTS: We evaluated 262 patients (142 male; age 74 +/- 12 years) without documented AF who underwent PPM implantation for sinus node dysfunction (n = 122) or atrioventricular block (n = 140). Information regarding patient demographics, cardiovascular diseases, and medication history was obtained. The cumulative percentages of ventricular pacing as well as the frequency, duration, and time to first episode of an AHRE were also determined. During follow-up of 596 +/- 344 days, an AHRE > or = 5 minutes was detected in 77 (29%) patients. Of these, 47 (61%) patients had an AHRE > or = 1 hour, 22 (29%) patients had an AHRE > or = 1 day, and 12 (16%) patients had an AHRE > or = 1 week. An AHRE > or = 5 minutes was seen in 24% and 34% of patients at 1 year and 2 years, respectively. Among patients with sinus node dysfunction, > or = 50% cumulative ventricular pacing was the only significant predictor of an AHRE > or = 5 minutes (HR 2.2; CI 1.0-4.7; P = 0.04).
CONCLUSIONS: Within 1 year of PPM implantation, AF is detected in 24% of patients without history of AF. In patients with sinus node dysfunction, > or = 50% cumulative right ventricular pacing is associated with a 2-fold increase in risk of developing AF.

Entities:  

Mesh:

Year:  2006        PMID: 17081212     DOI: 10.1111/j.1540-8167.2006.00648.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  17 in total

1.  ISHNE/EHRA expert consensus on remote monitoring of cardiovascular implantable electronic devices (CIEDs).

Authors:  Sergio Dubner; Angelo Auricchio; Jonathan S Steinberg; Panos Vardas; Peter Stone; Josep Brugada; Ryszard Piotrowicz; David L Hayes; Paulus Kirchhof; Günter Breithardt; Wojciech Zareba; Claudio Schuger; Mehmet K Aktas; Michal Chudzik; Suneet Mittal; Niraj Varma
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-01       Impact factor: 1.468

2.  Subclinical atrial fibrillation frequency and associated parameters in patients with cardiac resynchronization therapy.

Authors:  Mehmet Uğurlu; Onur Kaypakli; Durmuş Yıldıray Şahin; Yahya Kemal Içen; İbrahim Halil Kurt; Mevlüt Koç
Journal:  J Interv Card Electrophysiol       Date:  2018-05-26       Impact factor: 1.900

3.  Efficacy of automatic mode switching in DDDR mode pacemakers: the most 2 study.

Authors:  Maurizio Santomauro; Luca Ottaviano; Alessio Borrelli; Gennaro Galasso; Carlo Duilio; Nicola Monteforte; Luigi Padeletti; Annibale Sandro Montenero; Peter Andrew; Massimo Chiariello
Journal:  J Interv Card Electrophysiol       Date:  2008-01-30       Impact factor: 1.900

4.  The Effects of Ranolazine on Paroxysmal Atrial Fibrillation in Patients with Coronary Artery Disease: A Preliminary Observational Study.

Authors:  Dionyssios Leftheriotis; Panayota Flevari; George Theodorakis; Angelos Rigopoulos; Ignatios Ikonomidis; Fotis Panou; Vassilios Sourides; Panagiotis Simitsis; Georgios Giannakakis; Isaac Aidonidis; Ioannis Rizos; Maria Anastasiou-Nana
Journal:  J Atr Fibrillation       Date:  2014-02-28

5.  Impact of high-grade atrioventricular block and cumulative frequent pacing on atrial arrhythmias.

Authors:  Eisha Wali; Amrish Deshmukh; Abdallah Bukari; Michael Broman; Zaid Aziz; Andrew Beaser; Gaurav Upadhyay; Hemal M Nayak; Roderick Tung; Cevher Ozcan
Journal:  Pacing Clin Electrophysiol       Date:  2018-07-16       Impact factor: 1.976

6.  The risk factors of new-onset atrial fibrillation after pacemaker implantation.

Authors:  Zhaodi Wu; Xueying Chen; Junbo Ge; Yangang Su
Journal:  Herz       Date:  2020-02-27       Impact factor: 1.443

Review 7.  Management of atrial high-rate episodes detected by cardiac implanted electronic devices.

Authors:  Ben Freedman; Giuseppe Boriani; Taya V Glotzer; Jeff S Healey; Paulus Kirchhof; Tatjana S Potpara
Journal:  Nat Rev Cardiol       Date:  2017-07-06       Impact factor: 32.419

8.  Atrial high-rates episodes: fact or fiction?

Authors:  Philasande Mkoko; Ashley Chin
Journal:  Cardiovasc J Afr       Date:  2021 Mar-Apr       Impact factor: 1.167

9.  Incidence and predictors of asymptomatic atrial fibrillation in patients older than 70 years with complete atrioventricular block and dual chamber pacemaker implantation.

Authors:  Vjekoslav Radeljić; Nikola Pavlović; Šime Manola; Diana Delić-Brkljačić; Hrvoje Pintarić; Dubravko Petrač
Journal:  Croat Med J       Date:  2011-02       Impact factor: 1.351

10.  Atrial Fibrillation Burden Detected by Dual-Chamber Pacemakers as a Predictor for Cardiac Outcomes: A Retrospective Single-Center Cohort Study.

Authors:  Song-Yun Chu; Jie Jiang; Yu-Ling Wang; Qin-Hui Sheng; Jing Zhou; Yan-Sheng Ding
Journal:  Front Cardiovasc Med       Date:  2021-06-25
View more