Literature DB >> 17080648

Use of multi-detector computed tomography for the detection of periprosthetic osteolysis in total knee arthroplasty.

Timothy G Reish1, Henry D Clarke, Giles R Scuderi, Kevin R Math, W Norman Scott.   

Abstract

This study determined the accuracy of plain radiography in detecting osteolytic lesions around total knee prostheses compared to multi-detector computed tomography (CT). Thirty-one patients diagnosed with periprosthetic osteolysis by multi-detector CT after total knee arthroplasty (TKA) were studied. Computed tomography for each patient was retrospectively reviewed in a blinded fashion. The plain radiographs for each patient that had been obtained prior to CT were reviewed in the same manner. The results of the CT were compared with the results of the radiographs. The number, size, and location of the lesions were compared. The multi-detector CT detected 48 lesions in 31 knees: 40 tibial lesions, 4 femoral lesions, and 4 patellar lesions. Radiographic diagnosis was made in 6 of the 40 tibial lesions, 2 of the 4 femoral lesions, and 0 of the 4 patellar lesions. Plain radiographs are inadequate for evaluating periprosthetic osteolysis in TKA with only 8 (17%) of 48 lesions detected by multi-detector CT visible on the standard radiographs. Multi-detector CT provides the surgeon with a diagnostic and preoperative planning tool when osteolysis is suspected.

Entities:  

Mesh:

Year:  2006        PMID: 17080648     DOI: 10.1055/s-0030-1248116

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  4 in total

1.  Impaction bone grafting for the reconstruction of large bone defects in revision knee arthroplasty.

Authors:  M Rudert; B M Holzapfel; E von Rottkay; D E Holzapfel; U Noeth
Journal:  Oper Orthop Traumatol       Date:  2015-02-04       Impact factor: 1.154

2.  Imaging in peri-prosthetic assessment: an orthopaedic perspective.

Authors:  Christoph H Lohmann; Sanjiv Rampal; Martin Lohrengel; Gurpal Singh
Journal:  EFORT Open Rev       Date:  2017-05-11

3.  Dual-energy CT and ceramic or titanium prostheses material reduce CT artifacts and provide superior image quality of total knee arthroplasty.

Authors:  Maximilian F Kasparek; Michael Töpker; Mathias Lazar; Michael Weber; Michael Kasparek; Thomas Mang; Paul Apfaltrer; Bernd Kubista; Reinhard Windhager; Helmut Ringl
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-06-07       Impact factor: 4.342

4.  A radiostereometric and clinical long-term follow-up study of the surface replacement trapeziometacarpal joint prosthesis.

Authors:  Bart Ten Brinke; Nina M C Mathijssen; Ian F Blom; Lennard A Koster; Gerald A Kraan
Journal:  BMC Musculoskelet Disord       Date:  2021-02-05       Impact factor: 2.362

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.