Literature DB >> 17068700

In vitro comparison of frictional torque and torsional resistance of aged conventional gamma-in-nitrogen sterilized polyethylene versus aged highly crosslinked polyethylene articulating against head sizes larger than 32 mm.

Brian R Burroughs1, Orhun K Muratoglu, Charles R Bragdon, Keith K Wannomae, Steven Christensen, Andrew J Lozynsky, William H Harris.   

Abstract

BACKGROUND: The advent of highly crosslinked polyethylene has allowed the re-evaluation of the use of femoral heads larger than 32 mm for metal-on-polyethylene total hip arthroplasties. However, the effect of larger heads on the frictional torque of highly crosslinked polyethylene is unknown.
METHODS: We performed an in vitro examination of the effect of larger chrome cobalt femoral heads (40 mm diameter) on the frictional torque and torsional resistance of hip articulations on aged liners of polyethylene that were sterilized by gamma rays while in nitrogen, and aged highly crosslinked polyethylene. The frictional torque at the femoral head articulation was usually higher for the highly crosslinked polyethylene than for the conventional polyethylene. The aged conventional liners oxidized considerably, which led to gross failure of the polyethylene at the anti-rotation portion of the rim. The aged crosslinked polyethylene showed no such failures despite the higher frictional torque.
INTERPRETATION: Our findings suggest that in terms of torsional resistance to fatigue when studied as a device, rather than as an isolated material, under these conditions, aged highly crosslinked polyethylene is preferable to aged conventional polyethylene.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17068700     DOI: 10.1080/17453670610012881

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  11 in total

1.  Squeaking: Current knowledge and how to avoid it.

Authors:  Arjuna M Imbuldeniya; Simon J Pearce; William L Walter; Bernard A Zicat; William K Walter
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

Review 2.  What is the trouble with trunnions?

Authors:  Christina I Esposito; Timothy M Wright; Stuart B Goodman; Daniel J Berry
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

3.  Modern trunnions are more flexible: a mechanical analysis of THA taper designs.

Authors:  David A Porter; Robert M Urban; Joshua J Jacobs; Jeremy L Gilbert; José A Rodriguez; H John Cooper
Journal:  Clin Orthop Relat Res       Date:  2014-09-30       Impact factor: 4.176

4.  Backside Wear Is Not Dependent on the Acetabular Socket Design in Crosslinked Polyethylene Liners.

Authors:  Kamal Bali; Richard W McCalden; Douglas D R Naudie; Steven J MacDonald; Matthew G Teeter
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

5.  Does increased diameter of metal femoral head associated with highly cross-linked polyethylene augment stress on the femoral stem and cortical hypertrophy?

Authors:  Seiya Ishii; Yasuhiro Homma; Tomonori Baba; Yuichi Shirogane; Kazuo Kaneko; Muneaki Ishijima
Journal:  Int Orthop       Date:  2021-02-22       Impact factor: 3.075

6.  Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions?

Authors:  Robin Pourzal; Deborah J Hall; Nguyen Q Ha; Robert M Urban; Brett R Levine; Joshua J Jacobs; Hannah J Lundberg
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

7.  Low failure rate at short term for 40 mm heads and second generation triple annealed HCLPE liners in hybrid hip replacements.

Authors:  Rajkumar Thangaraj; Jan Kuiper; Ralph D Perkins
Journal:  J Clin Orthop Trauma       Date:  2018-01-03

8.  Taper junction failure in large-diameter metal-on-metal bearings.

Authors:  D J Langton; R Sidaginamale; J K Lord; A V F Nargol; T J Joyce
Journal:  Bone Joint Res       Date:  2012-04-01       Impact factor: 5.853

9.  A case of a C-stem fracture at the head-neck junction and a review of the literature.

Authors:  David Morley; Ian Starks; Justin Lim
Journal:  Case Rep Orthop       Date:  2012-12-09

10.  Peri-acetabular bone mineral densityin total hip replacement.

Authors:  L Gauthier; L Dinh; P E Beaulé
Journal:  Bone Joint Res       Date:  2013-08-02       Impact factor: 5.853

View more