Literature DB >> 17065761

First clinical and biomechanical results of the Trochanteric Fixation Nail (TFN).

A Lenich1, J Fierlbeck, A Al-Munajjed, S Dendorfer, R Mai, B Füchtmeier, E Mayr, J Hammer.   

Abstract

Conventional osteosynthesis of proximal femur fractures is still affected by serious complication rates between 4-18%, even though advanced implant modifications and surgical techniques are common practice. In terms of increasing age and co-morbidity of patients this complication ratio is expected to increase even further in the immediate future. One major reason for implant failure is the decreasing stability potential of the implant due to a loss in mechanical properties of cancellous bone. Therefore, efforts in new intramedulary techniques specifically focus on the load bearing characteristics of the implant by developing new geometries to improve the implant-tissue interface. This investigation discusses first clinical results of the trochanteric fixation nail TFN (145 patients) and a biomechanical analysis of the blade/femur head interaction under different static loading conditions. The TFN shows promising performance in first clinical results. In the clinical study the overall complication rate was significantly lower compared to other similar osteosynthesis. For the investigation of the biomechanical stability of the helical TFN blade the following experiments were performed: Analysis of the axial load required for insertion of the blade by free rotation; measurement of the corresponding rotation angle for total insertion (32 mm) (n = 8); pull-out forces with suppressed rotation (n = 4); loads for rotational overwinding of the implant in the fully inserted condition (n = 4). All investigations were performed on human femoral heads. The bone mineral densities of the specimens were detected by QCT-scans. Prior to cadaveric testing the experimental set-up was validated (n = 8) by the use of synthetic foam blocks (Sawbone).

Entities:  

Mesh:

Year:  2006        PMID: 17065761

Source DB:  PubMed          Journal:  Technol Health Care        ISSN: 0928-7329            Impact factor:   1.285


  4 in total

1.  Is the rotation of the femoral head a potential initiation for cutting out? A theoretical and experimental approach.

Authors:  Andreas Lenich; Samuel Bachmeier; Lukas Prantl; Michael Nerlich; Jochen Hammer; Edgar Mayr; Amir Andreas Al-Munajjed; Bernd Füchtmeier
Journal:  BMC Musculoskelet Disord       Date:  2011-04-22       Impact factor: 2.362

Review 2.  Intertrochanteric fractures: a review of fixation methods.

Authors:  Senthil Nathan Sambandam; Jayadev Chandrasekharan; Varatharaj Mounasamy; Cyril Mauffrey
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-03-30

3.  Functional and Radiological Outcome of Unstable Intertrochanteric Fracture Post Dynamic Hip Screw Fixation.

Authors:  Muhammad T Lakho; Asif A Jatoi; Muhammad Khanzada Azfar; Aijaz Ali; Safiya Javed; Anisuddin Bhatti; Musa Karim
Journal:  Cureus       Date:  2019-04-01

4.  Treatment of Unstable Intertrochanteric Fractureswith Proximal Femoral Nail Antirotation II: Our Experience in Indian Patients.

Authors:  G N Kiran Kumar; Gaurav Sharma; Kavin Khatri; Kamran Farooque; Devendra Lakhotia; Vijay Sharma; Sanjay Meena
Journal:  Open Orthop J       Date:  2015-11-19
  4 in total