Literature DB >> 17061717

Wavefront analyzers induce instrument myopia.

Alejandro Cervino1, Sarah L Hosking, Gurjeet K Rai, Shezhad A Naroo, Bernard Gilmartin.   

Abstract

PURPOSE: To assess the accuracy of three wavefront analyzers versus a validated binocular open-view autorefractor in determining refractive error in non-cycloplegic eyes.
METHODS: Eighty eyes were examined using the SRW-5000 open-view infrared autorefractor and, in randomized sequence, three wavefront analyzers: 1) OPD-Scan (NIDEK, Gamagori, Japan), 2) WASCA (Zeiss/Meditec, Jena, Germany), and 3) Allegretto (WaveLight Laser Technologies AG, Erlangen, Germany). Subjects were healthy adults (19 men and 21 women; mean age: 20.8 +/- 2.5 years). Refractive errors ranged from +1.5 to -9.75 diopters (D) (mean: +1.83 +/- 2.74 D) with up to 1.75 D cylinder (mean: 0.58 +/- 0.53 D). Three readings were collected per instrument by one examiner without anticholinergic agents. Refraction values were decomposed into vector components for analysis, resulting in mean spherical equivalent refraction (M) and J0 and J45 being vectors of cylindrical power at 0 degrees and 45 degrees, respectively.
RESULTS: Positive correlation was observed between wavefront analyzers and the SRW-5000 for spherical equivalent refraction (OPD-Scan, r=0.959, P<.001; WASCA, r=0.981, P<.001; Allegretto, r=0.942, P<.001). Mean differences and limits of agreement showed more negative spherical equivalent refraction with wavefront analyzers (OPD-Scan, 0.406 +/- 0.768 D [range: 0.235 to 0.580 D] [P<.001]; WASCA, 0.511 +/- 0.550 D [range: 0.390 to 0.634 D] [P<.001]; and Allegretto, 0.434 +/- 0.904 D [range: 0.233 to 0.635 D] [P<.001]). A second analysis eliminating outliers showed the same trend but lower differences: OPD-Scan (n=75), 0.24 +/- 0.41 D (range: 0.15 to 0.34 D) (P<.001); WASCA (n=78), 0.46 +/- 0.47 D (range: 0.36 to 0.57 D) (P<.001); and Allegretto (n=77), 0.30 +/- 0.62 D (range: 0.16 to 0.44 D) (P<.001). No statistically significant differences were noted for J0 and J45.
CONCLUSIONS: Wavefront analyzer refraction resulted in 0.30 D more myopia compared to SRW-5000 refraction in eyes without cycloplegia. This is the result of the accommodation excess attributable to instrument myopia. For the relatively low degrees of astigmatism in this study (<2.0 D), good agreement was noted between wavefront analyzers and the SRW-5000.

Entities:  

Mesh:

Year:  2006        PMID: 17061717     DOI: 10.3928/1081-597X-20061001-10

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  6 in total

1.  Accuracy of wavefront aberrometer refraction vs manifest refraction in cataract patients: impact of age, ametropia and visual function.

Authors:  Jan O Huelle; Toam Katz; Jan Draeger; Milena Pahlitzsch; Vasyl Druchkiv; Johannes Steinberg; Gisbert Richard; Stephan J Linke
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-01-05       Impact factor: 3.117

2.  Spherical subjective refraction with a novel 3D virtual reality based system.

Authors:  Jaume Pujol; Juan Carlos Ondategui-Parra; Llorenç Badiella; Carles Otero; Meritxell Vilaseca; Mikel Aldaba
Journal:  J Optom       Date:  2016-02-05

3.  Quality of eyeglass prescriptions from a low-cost wavefront autorefractor evaluated in rural India: results of a 708-participant field study.

Authors:  Nicholas J Durr; Shivang R Dave; Daryl Lim; Sanil Joseph; Thulasiraj D Ravilla; Eduardo Lage
Journal:  BMJ Open Ophthalmol       Date:  2019-06-14

4.  Agreement of wavefront-based refraction, dry and cycloplegic autorefraction with subjective refraction.

Authors:  Shahram Bamdad; Hamed Momeni-Moghaddam; Milad Abdolahian; David P Piñero
Journal:  J Optom       Date:  2020-09-28

Review 5.  Dioptric power and refractive behaviour: a review of methods and applications.

Authors:  Alan Rubin; Tanya Evans; Nabeela Hasrod
Journal:  BMJ Open Ophthalmol       Date:  2022-04-01

6.  Precision and agreement of higher order aberrations measured with ray tracing and Hartmann-Shack aberrometers.

Authors:  Zequan Xu; Yanjun Hua; Wei Qiu; Guoqiang Li; Qiang Wu
Journal:  BMC Ophthalmol       Date:  2018-01-27       Impact factor: 2.209

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.