Scanning orientation effects on Gafchromic EBT film dosimetry.

M J Butson1, T Cheung, P K N Yu.   

Abstract

Gafchromic EBT film, a new high sensitivity radiochromic film has been tested for variations in optical properties due to scanning orientation. Gafchromic EBT film has been shown to produce a scanning orientation effect whereby variations in measured relative optical density are found due to the films orientation relative to the scanner direction. This relative optical density change was found to be relatively consistent for different films exposed to varying dose levels ranging from 0 Gy to 3 Gy. A maximum variation of 0.0157 +/- 0.0035 in optical density (OD) was found. This relates to an approximate 15% variation in net OD for a 50 cGy irradiated film and 4% variation for a 3 Gy irradiated film. No noticeable effects or variations were seen with changing scanning resolution or with the film placed "up or down" during scanning. Other Gafchromic film types were tested and compared to EBT for unirradiated film to assess the magnitude of this orientation effect on the scanner used and results showed that EBT produced a significantly higher effect that MD-55-2, HS, XR type T and XR type R film by up to 3 times. As such, providing the same orientation of EBT film when scanning for dosimetric analysis becomes an essential part of EBT film dosimetry.

Entities:  

Mesh:

Year:  2006        PMID: 17058592     DOI: 10.1007/bf03178579

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  15 in total

1.  Precise film dosimetry for stereotactic radiosurgery and stereotactic body radiotherapy quality assurance using Gafchromic™ EBT3 films.

Authors:  Ning Wen; Siming Lu; Jinkoo Kim; Yujiao Qin; Yimei Huang; Bo Zhao; Chang Liu; Indrin J Chetty
Journal:  Radiat Oncol       Date:  2016-10-04       Impact factor: 3.481

2.  The use of radiochromic EBT2 film for the quality assurance and dosimetric verification of 3D conformal radiotherapy using Microtek ScanMaker 9800XL flatbed scanner.

Authors:  G S Sim; J H D Wong; K H Ng
Journal:  J Appl Clin Med Phys       Date:  2013-07-08       Impact factor: 2.102

3.  Comparison of trigeminal neuralgia radiosurgery plans using two film detectors for the commissioning of small photon beams.

Authors:  Karina P Esparza-Moreno; Olivia A García-Garduño; Paola Ballesteros-Zebadúa; José M Lárraga-Gutiérrez; Sergio Moreno-Jiménez; Miguel A Celis-Lopez
Journal:  J Appl Clin Med Phys       Date:  2013-11-04       Impact factor: 2.102

4.  Comparison of Epson scanner quality for radiochromic film evaluation.

Authors:  Hani Alnawaf; Peter K N Yu; Martin Butson
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

5.  Small field electron beam dosimetry using MOSFET detector.

Authors:  Md Nurul Amin; Robert Heaton; Bern Norrlinger; Mohammad K Islam
Journal:  J Appl Clin Med Phys       Date:  2010-10-04       Impact factor: 2.102

6.  Reference dosimetry using radiochromic film.

Authors:  Frédéric Girard; Hugo Bouchard; Frédéric Lacroix
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

7.  Characterization of MOSkin detector for in vivo skin dose measurement during megavoltage radiotherapy.

Authors:  Wei Loong Jong; Jeannie Hsiu Ding Wong; Ngie Min Ung; Kwan Hoong Ng; Gwo Fuang Ho; Dean L Cutajar; Anatoly B Rosenfeld
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

8.  Radiation transmission, leakage and beam penumbra measurements of a micro-multileaf collimator using GafChromic EBT film.

Authors:  Olivia Amanda García-Garduño; Miguel Angel Celis; José Manuel Lárraga-Gutiérrez; Sergio Moreno-Jiménez; Arnulfo Martínez-Dávalos; Mercedes Rodríguez-Villafuerte
Journal:  J Appl Clin Med Phys       Date:  2008-06-23       Impact factor: 2.102

9.  Suitability of radiochromic films for dosimetry of very-low energy X-rays.

Authors:  Martin A Ebert; Ali H Asad; Salim A Siddiqui
Journal:  J Appl Clin Med Phys       Date:  2009-09-02       Impact factor: 2.102

10.  Volumetric-modulated Arc Therapy Lung Stereotactic Body Radiation Therapy Dosimetric Quality Assurance: A Comparison between Radiochromic Film and Chamber Array.

Authors:  Juan Fernando Mata Colodro; Alfredo Serna Berná; Vicente Puchades Puchades; David Ramos Amores; Miguel Alcaraz Baños
Journal:  J Med Phys       Date:  2017 Jul-Sep
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.