Comparison of scatter doses from a multislice and a single slice CT scanner.

J W Burrage1, D A Causer.   

Abstract

During shielding calculations for a new multislice CT (MSCT) scanner it was found that the manufacturer's data indicated significantly higher external scatter doses than would be generated for a single slice CT (SSCT). Even allowing for increased beam width, the manufacturer's data indicated that the scatter dose per scan was higher by a factor of about 3 to 4. The magnitude of the discrepancy was contrary to expectations and also contrary to a statement by the UK ImPACT group, which indicated that when beam width is taken into account, the scatter doses should be similar. The matter was investigated by comparing scatter doses from an SSCT and an MSCT. Scatter measurements were performed at three points using a standard perspex CTDI phantom, and CT dose indices were also measured to compare scanner output. MSCT measurements were performed with a 40 mm wide beam, SSCT measurements with a 10 mm wide beam. A film badge survey was also performed after the installation of the MSCT scanner to assess the adequacy of lead shielding in the room. It was found that the scatter doses from the MSCT were lower than indicated by the manufacturer's data. MSCT scatter doses were approximately 4 times higher than those from the SSCT, consistent with expectations due to beam width differences. The CT dose indices were similar, and the film badge survey indicated that the existing shielding, which had been adequate for the SSCT, was also adequate for the MSCT.

Mesh:

Year:  2006        PMID: 17058587     DOI: 10.1007/bf03178574

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  2 in total

1.  EANM guidelines for ventilation/perfusion scintigraphy : Part 2. Algorithms and clinical considerations for diagnosis of pulmonary emboli with V/P(SPECT) and MDCT.

Authors:  M Bajc; J B Neilly; M Miniati; C Schuemichen; M Meignan; B Jonson
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-09       Impact factor: 9.236

2.  A new shielding calculation method for X-ray computed tomography regarding scattered radiation.

Authors:  Hiroshi Watanabe; Kimiya Noto; Tomokazu Shohji; Yasuyoshi Ogawa; Toshioh Fujibuchi; Ichiro Yamaguchi; Hitoshi Hiraki; Tetsuo Kida; Kazutoshi Sasanuma; Yasushi Katsunuma; Takurou Nakano; Genki Horitsugi; Makoto Hosono
Journal:  Radiol Phys Technol       Date:  2016-12-26
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.