Literature DB >> 17056294

Using computational simulation to aid in the prediction of socket fit: a preliminary study.

Winson C C Lee1, Ming Zhang.   

Abstract

This study illustrates the use of computational analysis to predict prosthetic socket fit. A simple indentation test is performed by applying force to the residual limb of a trans-tibial amputee through an indenter until the subject perceives the onset of pain. Computational finite element (FE) analysis is then applied to evaluate the magnitude of pressure underlying the indenter that initiates pain (pain threshold pressure), and the pressure at the prosthetic socket-residual limb interface. The assessment of socket fit is examined by studying whether or not the socket-limb interface pressure exceeds the pain threshold pressure of the limb. Based on the computer-aided assessment, a new prosthetic socket is then fabricated and fitted to the amputee subject. Successful socket fit is achieved at the end of this process. The approach of using computational analysis to aid in assessing socket fit allows a more efficient evaluation and re-design of the socket even before the actual fabrication and fitting of the prosthetic socket. However, more thorough investigations are required before this approach can be widely used. A subsequent part of this paper discusses the limitations and suggests future research directions in this area.

Entities:  

Mesh:

Year:  2006        PMID: 17056294     DOI: 10.1016/j.medengphy.2006.09.008

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  5 in total

1.  Computer-socket manufacturing error: how much before it is clinically apparent?

Authors:  Joan E Sanders; Michael R Severance; Kathryn J Allyn
Journal:  J Rehabil Res Dev       Date:  2012

2.  Efficient Computation of Cartilage Contact Pressures within Dynamic Simulations of Movement.

Authors:  Colin R Smith; Kwang Won Choi; Dan Negrut; Darryl G Thelen
Journal:  Comput Methods Biomech Biomed Eng Imaging Vis       Date:  2016-05-13

3.  A finite element model to assess transtibial prosthetic sockets with elastomeric liners.

Authors:  John C Cagle; Per G Reinhall; Kate J Allyn; Jake McLean; Paul Hinrichs; Brian J Hafner; Joan E Sanders
Journal:  Med Biol Eng Comput       Date:  2017-12-13       Impact factor: 2.602

Review 4.  Review of the socket design and interface pressure measurement for transtibial prosthesis.

Authors:  Gh Pirouzi; N A Abu Osman; A Eshraghi; S Ali; H Gholizadeh; W A B Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-13

5.  Reference data on thickness and mechanics of tissue layers and anthropometry of musculoskeletal extremities.

Authors:  Erica E Neumann; Tammy M Owings; Tyler Schimmoeller; Tara F Nagle; Robb W Colbrunn; Benjamin Landis; J Eric Jelovsek; Mike Wong; Joy P Ku; Ahmet Erdemir
Journal:  Sci Data       Date:  2018-09-25       Impact factor: 6.444

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.