Literature DB >> 17048029

Accuracy of cone beam dental CT, intraoral digital and conventional film radiography for the detection of periapical lesions. An ex vivo study in pig jaws.

Andreas Stavropoulos1, Ann Wenzel.   

Abstract

To compare the accuracy of cone beam CT scanning (NewTom 3G) with intraoral periapical radiography (Dixi2, Planmeca CCD sensor and Insight film) for the detection of periapical bone defects. Ten frozen pig mandibles were used. All soft tissues were removed and the jaws were sagittally sectioned to obtain three blocks from each side of the jaw containing the premolars and the molars with surrounding jaw bone. All teeth with intact roots were then "extracted". First, 15 blocks were used to define defect size and exposure parameters; then, the remaining 45 blocks were divided into three equal groups. In one group, cylindrical defects of 1 x 1 mm were prepared beyond the apices of the extraction sockets, in another group defects of 2 x 2 mm were similarly prepared, while no defects were prepared in the last group. The teeth were replaced into their sockets and digital and conventional radiographs of all blocks were taken under reproducible conditions. In addition, all blocks were CT scanned with the same volumetric data and then reconstructed to provide sagittal and coronal 2-D sections. Masked evaluation of the images (defect present vs no defect) was performed by four calibrated examiners. Statistical analysis was performed with ANOVA and the significance level was set to P < 0.05. NewTom 3G was statistically significantly better in terms of sensitivity (54%), positive (82.6%) and negative (44.5%) predictive values, and diagnostic accuracy (61%) when compared with digital radiographs (23%, 60%, 31%, 39%), and with conventional ones (28%, 70%, 35%, 44%)-except in the positive predictive value. Specificity was similar for all three methods. No difference was observed between the two periapical (digital vs conventional) radiographs. NewTom 3G may be useful in cases of immediate implants intended to replace teeth with suspicion for possible existing endodontic pathology, or in candidate implant sites neighboring such teeth.

Entities:  

Mesh:

Year:  2006        PMID: 17048029     DOI: 10.1007/s00784-006-0078-8

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  33 in total

Review 1.  The first two-stage dental implant system and its clinical application.

Authors:  D van Steenberghe; I Naert
Journal:  Periodontol 2000       Date:  1998-06       Impact factor: 7.589

2.  Roentgenographic and direct observation of experimental lesions in bone: I. 1961.

Authors:  I B Bender; Samuel Seltzer
Journal:  J Endod       Date:  2003-11       Impact factor: 4.171

3.  Roentgenographic and direct observation of experimental lesions in bone: II. 1961.

Authors:  I B Bender; Samuel Seltzer
Journal:  J Endod       Date:  2003-11       Impact factor: 4.171

4.  Radiological visibility of small artificial periapical bone lesions.

Authors:  S D Bianchi; M Roccuzzo; N Cappello; A Libero; S Rendine
Journal:  Dentomaxillofac Radiol       Date:  1991-02       Impact factor: 2.419

5.  Diagnostic accuracy of direct digital dental radiography for the detection of periapical bone lesions. II. Effects on diagnostic accuracy after application of image processing.

Authors:  B Kullendorff; M Nilsson
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1996-11

6.  The effect of periradicular endodontic pathosis on the apical region of adjacent implants.

Authors:  M D Shaffer; D A Juruaz; P C Haggerty
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1998-11

7.  Interpretation of periapical lesions comparing conventional, direct digital, and telephonically transmitted radiographic images.

Authors:  E J Mistak; R J Loushine; P D Primack; L A West; D A Runyan
Journal:  J Endod       Date:  1998-04       Impact factor: 4.171

8.  A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results.

Authors:  P Mozzo; C Procacci; A Tacconi; P T Martini; I A Andreis
Journal:  Eur Radiol       Date:  1998       Impact factor: 5.315

9.  Immediate placement of implants into extraction sockets: implant survival.

Authors:  B Rosenquist; B Grenthe
Journal:  Int J Oral Maxillofac Implants       Date:  1996 Mar-Apr       Impact factor: 2.804

Review 10.  The implant periapical lesion: etiology, prevention, and treatment.

Authors:  G M Reiser; M Nevins
Journal:  Compend Contin Educ Dent       Date:  1995-08
View more
  27 in total

1.  Cone-beam computed tomography in assessment of periodontal ligament space: in vitro study on artificial tooth model.

Authors:  Nurdan Ozmeric; Irina Kostioutchenko; Georg Hägler; Matthias Frentzen; Pia-Merete Jervøe-Storm
Journal:  Clin Oral Investig       Date:  2008-02-05       Impact factor: 3.573

2.  LCD and CRT display of storage phosphor plate and limited cone beam computed tomography images for the evaluation of root canal fillings.

Authors:  B Güniz Baksi; Elif Soğur; Hans-Göran Gröndahl
Journal:  Clin Oral Investig       Date:  2008-07-30       Impact factor: 3.573

3.  Noise power properties of a cone-beam CT system for breast cancer detection.

Authors:  Kai Yang; Alexander L C Kwan; Shih-Ying Huang; Nathan J Packard; John M Boone
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

4.  Comparison of cone beam CT device and field of view for the detection of simulated periapical bone lesions.

Authors:  M Hedesiu; M Baciut; G Baciut; O Nackaerts; R Jacobs
Journal:  Dentomaxillofac Radiol       Date:  2012-05-03       Impact factor: 2.419

5.  Comparative assessment of periapical radiography and CBCT imaging for radiodiagnostics in the posterior maxilla.

Authors:  Maryam Shahbazian; Charlotte Vandewoude; Jan Wyatt; Reinhilde Jacobs
Journal:  Odontology       Date:  2013-12-28       Impact factor: 2.634

6.  Construction of three-dimensional tooth model by micro-computed tomography and application for data sharing.

Authors:  A Kato; N Ohno
Journal:  Clin Oral Investig       Date:  2008-04-03       Impact factor: 3.573

7.  Clinical and radiographic assessment of the efficacy of calcium silicate indirect pulp capping: a randomized controlled clinical trial.

Authors:  D Hashem; F Mannocci; S Patel; A Manoharan; J E Brown; T F Watson; A Banerjee
Journal:  J Dent Res       Date:  2015-02-20       Impact factor: 6.116

8.  Detection of cavitated approximal surfaces using cone beam CT and intraoral receptors.

Authors:  A Wenzel; E Hirsch; J Christensen; L H Matzen; G Scaf; M Frydenberg
Journal:  Dentomaxillofac Radiol       Date:  2012-07-27       Impact factor: 2.419

9.  A comparison of the diagnostic accuracy of in vivo and in vitro photostimulable phosphor digital images in the detection of occlusal caries lesions.

Authors:  K Kamburoglu; B Senel; S P Yüksel; T Ozen
Journal:  Dentomaxillofac Radiol       Date:  2010-01       Impact factor: 2.419

10.  Use of cone beam computed tomography in endodontics.

Authors:  William C Scarfe; Martin D Levin; David Gane; Allan G Farman
Journal:  Int J Dent       Date:  2010-03-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.