Literature DB >> 17045874

Assessment by transient elastography of the viscoelastic properties of blood during clotting.

Jean-Luc Gennisson1, Sophie Lerouge, Guy Cloutier.   

Abstract

Blood clotting is a natural process that can be both beneficial and life-threatening for the human body. It allows the maintenance of hemostasis after vascular injury, but it can also cause deep vein thrombosis and heart stroke. This study aimed better to understand the clotting process from a biomechanical point of view by using an acoustic method. The long-term objective is the staging of the age of clots in deep veins for therapy planning. The transient elastography method using a shear elasticity probe served to evaluate the shear wave velocity (V(S)) and shear wave attenuation (alpha(S)) of porcine whole blood during in vitro clot formation. By solving an inverse problem, it was then possible to provide images of the elasticity (mu(B)) and of the viscosity (eta(B)) from clotting blood. The time-varying elasticity and viscosity were very similar to what has been observed for the sol-gel transition of polymers. The mechanical properties of blood clot, which were modified by varying the hematocrit and by adding heparin or fibrinogen, were clearly assessed by the transient elastography technique. It is concluded that the shear elasticity probe is an appropriate tool to quantify and follow the sol-gel transition of blood during clotting.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17045874     DOI: 10.1016/j.ultrasmedbio.2006.06.008

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  15 in total

1.  AN OVERVIEW OF ELASTOGRAPHY - AN EMERGING BRANCH OF MEDICAL IMAGING.

Authors:  Armen Sarvazyan; Timothy J Hall; Matthew W Urban; Mostafa Fatemi; Salavat R Aglyamov; Brian S Garra
Journal:  Curr Med Imaging Rev       Date:  2011-11

2.  Subzone based magnetic resonance elastography using a Rayleigh damped material model.

Authors:  Elijah E W Van Houten; D vR Viviers; M D J McGarry; P R Perriñez; I I Perreard; J B Weaver; K D Paulsen
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

Review 3.  The pathophysiology, diagnosis and treatment of the acute coagulopathy of trauma and shock: a literature review.

Authors:  J Kaczynski; M Wilczynska; L Fligelstone; J Hilton
Journal:  Eur J Trauma Emerg Surg       Date:  2013-12-12       Impact factor: 3.693

4.  Assessing blood coagulation status with laser speckle rheology.

Authors:  Markandey M Tripathi; Zeinab Hajjarian; Elizabeth M Van Cott; Seemantini K Nadkarni
Journal:  Biomed Opt Express       Date:  2014-02-24       Impact factor: 3.732

5.  In vitro assessment of effects of hyperglycemia on the optical properties of blood during coagulation using optical coherence tomography.

Authors:  Ying Liu; Guoyong Wu; Huajiang Wei; Zhouyi Guo; Hongqin Yang; Yonghong He; Shusen Xie; Yuqing Zhang; Zhenguo Zhu
Journal:  Lasers Med Sci       Date:  2014-11-08       Impact factor: 3.161

6.  Error in estimates of tissue material properties from shear wave dispersion ultrasound vibrometry.

Authors:  Matthew W Urban; Shigao Chen; James F Greenleaf
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-04       Impact factor: 2.725

7.  Quantitative sonoelastography for the in vivo assessment of skeletal muscle viscoelasticity.

Authors:  Kenneth Hoyt; Timothy Kneezel; Benjamin Castaneda; Kevin J Parker
Journal:  Phys Med Biol       Date:  2008-07-08       Impact factor: 3.609

8.  Development of in situ-forming hydrogels for hemorrhage control.

Authors:  Henry T Peng; Pang N Shek
Journal:  J Mater Sci Mater Med       Date:  2009-04-04       Impact factor: 3.896

9.  A Review of Shearwave Dispersion Ultrasound Vibrometry (SDUV) and its Applications.

Authors:  Matthew W Urban; Shigao Chen; Mostafa Fatemi
Journal:  Curr Med Imaging Rev       Date:  2012-02-01

Review 10.  Acoustic waves in medical imaging and diagnostics.

Authors:  Armen P Sarvazyan; Matthew W Urban; James F Greenleaf
Journal:  Ultrasound Med Biol       Date:  2013-04-30       Impact factor: 2.998

View more