Literature DB >> 1704547

Intrapatient comparison between chronic VVIR and DDD pacing in patients affected by high degree AV block without heart failure.

C Menozzi1, M Brignole, P V Moracchini, G Lolli, M Bacchi, M C Tesorieri, G D Tosoni, R Bollini.   

Abstract

In patients affected by high degree AV block without preexisting congestive heart failure there is no definite demonstration that DDD pacing gives real clinical advantages in respect to VVIR pacing. We performed an intrapatient, long-term study between the two pacing modes in 14 high degree AV block patients, using the Medtronic Synergyst 7027 dual chamber pacemaker, who could be programmed alternatively in DDD or VVIR mode. After a 4-week run-in period following the pacemaker implant, patients completed a randomized, double-blind, cross-over study to compare the effect of 6-week period VVIR and DDD pacing on symptoms and cardiovascular parameters. A semiquantitative score scale was used to quantify the symptoms of general well-being, palpitations, dizziness, pulsating sensation in the neck or abdomen, shortness of breath at rest and during effort, chest pain, and NYHA classification. The sum of symptom scores was 10.4 +/- 6.7 in VVIR period and 4.6 +/- 2.7 in DDD period (P less than 0.001); five patients (36%) crossed over early from VVIR to DDD because of intolerable symptoms; overall, eight patients preferred the DDD mode and no one preferred the VVIR. Cardiac output at rest (echo-Doppler method) was 4.7 +/- 1.4 versus 5.7 +/- 1.6 liter/min (P less than 0.01), body weight was 65.9 +/- 6.6 versus 64.9 +/- 6.1 kg (P less than 0.02), atrial natriuretic peptide was 236 +/- 112 versus 198 +/- 110 pg/mL (P less than 0.01), respectively, during VVIR and DDD modes. Effort tolerance was similar with the two modes of pacing (68 +/- 15 vs 70 +/- 18 watts/min).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 1704547     DOI: 10.1111/j.1540-8159.1990.tb06896.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  Long-term outcome of atrial synchronous mode pacing in patients with atrioventricular block using a single lead.

Authors:  Miry Blich; Mahmoud Suleiman; Tawfiq Zeidan Shwiri; Ibrahim Marai; Monther Boulos; Shlomo Amikam
Journal:  Clin Cardiol       Date:  2010-01       Impact factor: 2.882

2.  Comparison of dual chamber and ventricular rate responsive pacing in patients over 75 with complete heart block.

Authors:  M R Hargreaves; K M Channon; T R Cripps; M Gardner; O J Ormerod
Journal:  Br Heart J       Date:  1995-10

Review 3.  Dual chamber versus single chamber ventricular pacemakers for sick sinus syndrome and atrioventricular block.

Authors:  J Dretzke; W D Toff; G Y H Lip; J Raftery; A Fry-Smith; R Taylor
Journal:  Cochrane Database Syst Rev       Date:  2004

Review 4.  Indications for permanent pacing in dogs and cats.

Authors:  R A Santilli; F Giacomazzi; D M Porteiro Vázquez; M Perego
Journal:  J Vet Cardiol       Date:  2019-01-29       Impact factor: 1.701

  4 in total