Literature DB >> 17043418

Mid-term follow up of patients using the St. Jude Medical Aortic Connector System for proximal vein graft in CABG.

Cheol Hyun Chung1, Jae Won Lee, Joon Kyu Kang, Hyun Song, Suk Jung Choo, Meong Gun Song.   

Abstract

The aortic connector system may reduce stroke during proximal venous anastomosis. However, the overall anastomotic patency rate has been generally reported to be low. From October 2002 to March 2004, 68 patients who received proximal anastomosis using the St. Jude Aortic Connector System were included in the study. There were 47 men and 21 women and their mean age was 65.68+/-6.68 yr old (52 to 85 yr). Grafts were evaluated by coronary angiography or multi-slice 16 channel 3-D CT at 6 days and at 6 months postoperatively. In the immediate postoperative period, no stenosis was observed by either angiography (n=22) or 3D CT (n=46). At 6-month postoperatively, we performed either angiography (n=7) or 3-D CT (n=52). Of these patients, 5 patients showed graft stenosis in the midportion, and 3 in the ostium. There were no stroke. Simple, and effective proximal anastomosis with good protection from cerebrovascular accident was achieved especially when calcification or atheromatous plaque was observed at the ascending aorta in the operation room. However, our mid term patency results raise concerns related to venous graft stenosis in the midportion. Therefore, longer follow up is recommended.

Entities:  

Mesh:

Year:  2006        PMID: 17043418      PMCID: PMC2721995          DOI: 10.3346/jkms.2006.21.5.849

Source DB:  PubMed          Journal:  J Korean Med Sci        ISSN: 1011-8934            Impact factor:   2.153


  19 in total

1.  The St Jude Medical symmetry aortic connector system for proximal vein graft anastomoses in coronary artery bypass grafting.

Authors:  Friedrich S Eckstein; Luis F Bonilla; Lars Englberger; Franz F Immer; Todd A Berg; Jürg Schmidli; Thierry P Carrel
Journal:  J Thorac Cardiovasc Surg       Date:  2002-04       Impact factor: 5.209

2.  Avoiding aortic clamping during coronary artery bypass using an automated anastomotic device.

Authors:  Munemoto Endo; Osama Benhameid; Jean F Morin; Hani Shennib
Journal:  Ann Thorac Surg       Date:  2002-03       Impact factor: 4.330

3.  Minimizing aortic manipulation during OPCAB using the symmetry aortic connector system for proximal vein graft anastomoses.

Authors:  F S Eckstein; L F Bonilla; L Englberger; E Stauffer; T A Berg; J Schmidli; T P Carrel
Journal:  Ann Thorac Surg       Date:  2001-09       Impact factor: 4.330

Review 4.  Early ostial saphenous vein graft stenosis associated with the use of Symmetry sutureless aortic proximal anastomosis device: successful percutaneous revascularization.

Authors:  Sharon L Cline; Anuradha Guduvalli; Vijay G Kalaria
Journal:  Catheter Cardiovasc Interv       Date:  2004-06       Impact factor: 2.692

5.  Early clinical experience with a new sutureless anastomotic device for proximal anastomosis of the saphenous vein to the aorta.

Authors:  A M Calafiore; Y Bar-El; G Vitolla; G Di Giammarco; G Teodori; A L Iacò; S D'Alessandro; M Di Mauro
Journal:  J Thorac Cardiovasc Surg       Date:  2001-05       Impact factor: 5.209

6.  Coronary bypass graft fate and patient outcome: angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years.

Authors:  G M Fitzgibbon; H P Kafka; A J Leach; W J Keon; G D Hooper; J R Burton
Journal:  J Am Coll Cardiol       Date:  1996-09       Impact factor: 24.094

7.  Use of verapamil and nitroglycerin solution in preparation of radial artery for coronary grafting.

Authors:  G W He; C Q Yang
Journal:  Ann Thorac Surg       Date:  1996-02       Impact factor: 4.330

8.  Verapamil plus nitroglycerin solution maximally preserves endothelial function of the radial artery: comparison with papaverine solution.

Authors:  G W He
Journal:  J Thorac Cardiovasc Surg       Date:  1998-06       Impact factor: 5.209

9.  Fatal complications after use of the Symmetry Aortic Connector in coronary artery bypass surgery.

Authors:  Jarmo Lahtinen; Fausto Biancari; Martti Mosorin; Jouni Heikkinen; Pekka Rainio; Tatu S Juvonen; Martti Lepojärvi
Journal:  Ann Thorac Surg       Date:  2004-05       Impact factor: 4.330

10.  Skeletonized radial artery graft with the St. Jude Medical Symmetry Bypass System (aortic connector system).

Authors:  Go Watanabe; Hirofumi Takemura; Shigeyuki Tomita; Hiroshi Nagamine; Hiroyuki Kamiya; Taro Kanamori
Journal:  Ann Thorac Surg       Date:  2004-05       Impact factor: 4.330

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.