Literature DB >> 11326228

Early clinical experience with a new sutureless anastomotic device for proximal anastomosis of the saphenous vein to the aorta.

A M Calafiore1, Y Bar-El, G Vitolla, G Di Giammarco, G Teodori, A L Iacò, S D'Alessandro, M Di Mauro.   

Abstract

BACKGROUND: Avoiding aortic side clamping is useful to avoid local particulate embolization. A device that allows a saphenous vein graft to be anastomosed to the aorta without aortic manipulation is clinically evaluated. METHODS AND
RESULTS: From July 1999 to March 2000, 17 patients who underwent myocardial revascularization had an aorta-saphenous vein graft anastomosis performed by means of an aortic anastomotic device. Eight were operated on with cardiopulmonary bypass and 9 without. The proximal anastomoses created by the aortic anastomotic device were performed before the institution of cardiopulmonary bypass or before the related distal anastomosis was performed. In 11 patients transcranial Doppler ultrasound was used. In 1 (6%) patient the saphenous vein graft was not deployed, and in 2 (12%) a single suture was added for minor bleeding. None of the 11 patients evaluated with transcranial Doppler ultrasound had evidence of particulate embolization during the procedure. No patient died or was reoperated on for bleeding. Six (35%) patients had a postoperative angiogram 48 +/- 26 days after the operation that showed widely patent proximal anastomoses.
CONCLUSIONS: Use of an aortic anastomotic device allows a sutureless anastomosis to be created between the aorta and saphenous vein graft. The device could be used in totally endoscopic myocardial revascularization. A second-generation device is ready to solve the problems encountered and to increase the ease in handling the device.

Entities:  

Mesh:

Year:  2001        PMID: 11326228     DOI: 10.1067/mtc.2001.112829

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  4 in total

1.  Mid-term follow up of patients using the St. Jude Medical Aortic Connector System for proximal vein graft in CABG.

Authors:  Cheol Hyun Chung; Jae Won Lee; Joon Kyu Kang; Hyun Song; Suk Jung Choo; Meong Gun Song
Journal:  J Korean Med Sci       Date:  2006-10       Impact factor: 2.153

2.  Initial clinical experience with the Heartstring.

Authors:  Toshinobu Kazui; Hirosato Doi; Masato Suzuki; Takashi Okamoto; Ryuji Koshima; Kenji Sugiki; Takemi Ohno
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2006-10

Review 3.  Coronary artery bypass grafts and MDCT imaging: what to know and what to look for.

Authors:  Riccardo Marano; Carlo Liguori; Pierluigi Rinaldi; Maria Luigia Storto; Marco Angelo Politi; Giancarlo Savino; Lorenzo Bonomo
Journal:  Eur Radiol       Date:  2007-09-15       Impact factor: 5.315

4.  The vascular connector, design of a new device for sutureless vascular anastomosis.

Authors:  Lulzim Vokrri; Xhavit Krasniqi; Arsim Qavdarbasha; Nexhmi Hyseni; Philippe Cinquin; Paolo Porcu; Carmine Sessa
Journal:  Ann Surg Innov Res       Date:  2014-11-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.